Hugging Face Trending Papers

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

The paper introduces Scalable Inverse Model (SIM), a framework that combines physics-based simulated training data, tailored model architecture, and learning strategies to achieve robust zero‑shot MRI reconstruction. By leveraging compute scaling, SIM overcomes data scarcity and demonstrates strong generalizability across 14 datasets from seven international centers, five vendors, multiple field strengths, anatomical regions, and acquisition protocols. Attention‑map analyses show that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy‑specific priors, enabling high‑quality reconstruction where conventional deep‑learning methods fail.

Hugging Face Trending Papers
Jun 13

Physics-Driven Zero-Shot MRI Reconstruction with Non-local Image Priors

Zero-Shot Self-Supervised Learning (ZS-SSL) has emerged as a promising paradigm for accelerated Magnetic Resonance Imaging (MRI) reconstruction, eliminating the reliance on fully-sampled external datasets. However, learning solely from a single under-sampled scan suffers from supervision scarcity and optimization instability, often leading to overfitting or artifacts.

arXiv Computer Vision
Aug 26

Single-Subject Multi-View MRI Super-Resolution via Implicit Neural Representations

The paper introduces SIMS-MRI, a self‑supervised framework that performs single‑subject multi‑view MRI super‑resolution using implicit neural representations. It processes anisotropic multi‑view scans without pre‑ or post‑processing, employing a multi‑resolution hash‑encoded representation and learned inter‑view alignment to produce isotropic reconstructions. The method is validated on simulated brain and clinical prostate MRI datasets, and the code will be publicly released.

By Heejong Kim, Abhishek Thanki, Roel van Herten, Daniel Margolis, Mert R Sabuncu
arXiv Computer Vision
Oct 12

Stochastic Finite-Transition Learning and Exploration for Accelerated MRI Reconstruction

The paper introduces FLEX‑MRI, a method that accelerates MRI reconstruction by partitioning the recovery process into a few finite intervals defined by progressive k‑space support changes. Instead of learning fine‑grained local dynamics, FLEX‑MRI directly learns the reconstruction change across each interval and employs stochastic exploration during inference to sample alternative transition paths. Experiments on multi‑coil MRI datasets demonstrate that FLEX‑MRI outperforms competing methods while keeping computational efficiency comparable to few‑step baselines.

By Muhammad Usama Mirza, Esin \"Ozt\"urk I\c{s}{\i}k, Tolga \c{C}ukur
Hugging Face Trending Papers
Jul 7

PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs.

arXiv Machine Learning
Aug 28

Quantitative mapping from conventional MRI using self-supervised physics-guided deep learning: applications to a large-scale, clinically heterogeneous dataset

This study introduces a self‑supervised, physics‑guided deep‑learning framework that converts standard clinical T1‑, T2‑, and FLAIR MRIs into quantitative T1, T2, and proton‑density maps. Trained on 4,121 scan sessions from four different 3 T scanners over six years, the method produces maps whose white‑ and gray‑matter values fall within literature ranges and shows minimal variation across scanner hardware and acquisition protocols (coefficients of variation ≤ 1.1 %). Voxel‑wise reproducibility is high, with Pearson and concordance correlation coefficients above 0.82 for T1 and T2 and mean relative differences below 6 % for T2.

By Jelmer van Lune, Stefano Mandija, Oscar van der Heide, Matteo Maspero, Martin B. Schilder, Jan Willem Dankbaar, Cornelis A. T. van den Berg, Alessandro Sbrizzi
arXiv AI
6d ago

Pathology Randomization for Synthetic Priors and Zero-Shot Detection

PathoDraw is a generative model that creates synthetic brain MRI scans with realistic pathology by conditioning lesion distributions on healthy anatomy. The model learns a contrast‑agnostic 3D UNet that estimates healthy anatomy and signed intensity deviations, enabling zero‑shot detection of stroke, tumor, and white matter hyperintensities across T1w, FLAIR, and T2w modalities and resolutions. It outperforms or matches contrast‑specific anomaly detectors trained on real scans, while preserving healthy anatomy and supporting downstream tasks such as super‑resolution and registration.

By Alexandra G. Roberts, Tonmoy Hossain, Mark Olchanyi, Stefan Brandst\"atter, Jonathan Williams Ramirez, Ana Lawry Aguila, Matthew Rosen, Annabel Sorby-Adams, W. Taylor Kimberly, Juan Eugenio Iglesias