Noise2Match is a self‑supervised method for low‑dose CT denoising that uses an adaptive inter‑slice matching network to model and correct the label transition between adjacent slices. By ensuring the equal‑mean condition of the Noise2Noise framework, it theoretically matches supervised training with paired noisy‑clean data. The approach also extends effectively to low‑dose cone‑beam CT, outperforming existing image‑domain self‑supervised methods.
arXiv:2603.25869v2 Announce Type: replace-cross
Abstract: Self-supervised image denoising methods have traditionally relied on architectural constraints, pseudo-pair constructions, or specialized los...
By Brayan Monroy, Jorge Bacca, Juli\'an Tachella
arXiv:2606. 00100v1 Announce Type: cross Abstract: Self-supervised deep learning-based methods have shown great promise for accelerated magnetic resonance imaging (MRI) reconstruction, achieving high image quality without requiring fully sampled data for training.
By Tongxi Song, Ziyu Li, Zihan Li, Wen Zhong, Congyu Liao, Yang Yang, Hua Guo, Wenchuan Wu, Qiyuan Tian
arXiv:2601.14180v5 Announce Type: replace
Abstract: Self-supervised learning has been increasingly investigated for low-dose computed tomography (LDCT) image denoising, as it alleviates the dependenc...
By Yichao Liu, Zongru Shao, Rui Wen, Yueyang Teng, Junwen Guo
arXiv:2611.22317v1 Announce Type: new
Abstract: Self-supervised denoising is challenging when the corruption is multiplicative and signal-dependent. In this letter, we propose SIDUMN, a symmetric noi...
By Nyan Htet Naing, Gyeongha Hwang
arXiv:2606. 02044v1 Announce Type: new Abstract: Diffusion MRI enables non-invasive probing of tissue microstructure, but accurate parameter estimation is challenged by noise-related effects.
By Bradley G. Karat, Ma\"eliss Jallais, Ali R. Khan, Santiago Aja-Fern\'andez, Jelle Veraart, Marco Palombo
The paper introduces CM-RED, a fast MRI reconstruction method that combines a pretrained consistency model with the regularization by denoising framework. By integrating controlled noise injection into accelerated proximal gradient updates, CM-RED achieves high‑quality reconstructions on fastMRI knee and brain datasets with only four network function evaluations. It consistently outperforms existing diffusion‑ and consistency‑based approaches in quantitative metrics, visual fidelity, and robustness to hyperparameter changes.
By Merve G\"ulle, Junno Yun, Ya\c{s}ar Utku Al\c{c}alar, Mehmet Ak\c{c}akaya
Diffusion MRI enables non-invasive probing of tissue microstructure, but accurate parameter estimation is challenged by noise-related effects. In supervised machine learning frameworks trained on simulated data, discrepancies between the noise characteristics of simulated and acquired signals introduce a form of covariate shift, whereby the input signal distribution differs between training and inference.
arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.
By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete. While learned reconstruction methods such as the Learned Primal-Dual algorithm achieve strong performance, they typically rely on supervised training with access to ground-truth data, which is often unavailable in practice.
arXiv:2607. 04069v1 Announce Type: cross Abstract: Cardiac cine Magnetic Resonance Imaging (MRI) is a critical diagnostic tool that provides dynamic insights for radiologists.
By Donghang Lyu, Marius Staring, Yiming Dong, Keupp Jochen, Hildo J. Lamb, Mariya Doneva
arXiv:2605. 12567v2 Announce Type: replace-cross Abstract: The inherent electronic and speckle noise complicates clinical interpretation of ultrasound images.
By Jiajing Zhang, Bingze Dai, Xi Zhang, Yue Xu, Wei-Ning Lee