arXiv:2606. 30951v1 Announce Type: cross Abstract: Micro-ultrasound ($\mu$US) is a new, emerging, and promising imaging modality for prostate cancer (PCa) detection, but accurate identification of suspicious tissue remains highly dependent on clinical experience, leading to substantial inter-observer variability.
By Mohammad Mahdi Abootorabi, Sina Namazi, Armin Saadat, Lyuyang Wang, Obed Dzikunu, Paul F. R. Wilson, Zhuoxin Guo, Brian Wodlinger, Parvin Mousavi, Purang Abolmaesumi
The paper introduces ANT, a test‑time adaptation framework that improves prostate cancer detection in micro‑ultrasound by performing a segmentation‑guided adaptation. ANT aligns a pretrained detection encoder to the target domain’s prostate anatomy using pseudo‑masks from a frozen segmentation network, thereby correcting domain‑specific feature drift while preserving cancer‑discriminative features. In a leave‑one‑center‑out evaluation, ANT raises mean AUC by 2.9% at the biopsy‑core level and 3.6% at the patient level compared to no adaptation, outperforming existing TTA baselines.
By Obed Korshie Dzikunu, Mohammad Mahdi Abootorabi, Mohamed Harmanani, Paul F. R. Wilson, Emma Willis, Ferdinand Luger, Adam Kinnaird, Brian Wodlinger, Parvin Mousavi, Purang Abolmaesumi
arXiv:2608. 14796v1 Announce Type: cross Abstract: Prostate cancer claims a life every 80 seconds.
By Ayusha Abbas, Saram Abbas, Kabita Adhikari
arXiv:2608.08374v3 Announce Type: replace
Abstract: Transformer models are increasingly used for whole-slide image analysis in computational pathology. Yet, WSIs differ fundamentally from natural ima...
By Zhiyuan Yang, Jiahao Cheng, Vincent Quoc-Huy Trinh, Mahdi S. Hosseini
arXiv:2606. 00092v1 Announce Type: cross Abstract: Weakly-supervised classification of whole-slide images with attention-based multiple instance learning (ABMIL) on top of foundation features now reaches near-saturation on Camelyon16 slide-level performance, but the corresponding attention maps are an imperfect localization signal: in clinical interpretation, a model that classifies correctly without firing on the actual lesion is hard to trust.
By Devansh Lalwani, Swapnil Bhat, Maulik Shah
HERO (Histology Encoder for Robust Representation in Oncology) is a ViT‑G/14 pathology foundation model trained with DINO and iBOT objectives and refined using high‑resolution Gram anchoring on a 500‑million‑tile corpus from about 575,000 clinical whole‑slide images. It demonstrates superior robustness to center, scanner, and stain variation compared to other state‑of‑the‑art foundation models, while maintaining competitive performance on tile‑level classification, segmentation, and gene‑expression prediction. Across 39 slide‑level clinical tasks, HERO ranks first on average and achieves the best average rank across six benchmark frameworks under an equal‑weighted analysis.
By Zhi Li (Caris Life Sciences, Irving, TX, United States), Eghbal Amidi (Caris Life Sciences, Irving, TX, United States), Yating Cheng (Caris Life Sciences, Irving, TX, United States), Tyson Dawson (Caris Life Sciences, Irving, TX, United States), Gorkem Can Ates (Caris Life Sciences, Irving, TX, United States), Shuzhen Kuang (Caris Life Sciences, Irving, TX, United States), Norsang Lama (Caris Life Sciences, Irving, TX, United States), Md Ashequr Rahman (Caris Life Sciences, Irving, TX, United States), Zhiying Lu (Caris Life Sciences, Irving, TX, United States), Elisabeth K. Kong (Caris Life Sciences, Irving, TX, United States), Milan Radovich (Caris Life Sciences, Irving, TX, United States), David Spetzler (Caris Life Sciences, Irving, TX, United States), Matthew Oberley (Caris Life Sciences, Irving, TX, United States), George W. Sledge (Caris Life Sciences, Irving, TX, United States), Ming Chen (Caris Life Sciences, Irving, TX, United States)
RACR-MIL is a weakly‑supervised method for grading squamous cell carcinoma (SCC) from whole‑slide images, using an attention‑based multiple‑instance learning framework. It introduces a hybrid WSI graph to capture local tissue context and non‑local phenotypic dependencies, and applies rank‑ordering constraints on attention to prioritize higher‑grade tumor regions, mirroring pathologists’ diagnostic reasoning. The approach achieves state‑of‑the‑art performance, improving SCC grading accuracy by 3–9% over existing methods and up to 10% in tumor localization, and a pilot study showed pathologists reported increased grading efficiency in 60% of cases.
By Anirudh Choudhary, Mosbah Aouad, Krishnakant Saboo, Angelina Hwang, Jacob Kechter, Blake Bordeaux, Puneet Bhullar, David DiCaudo, Steven Nelson, Nneka Comfere, Emma Johnson, Olayemi Sokumbi, Jason Sluzevich, Leah Swanson, Dennis Murphree, Aaron Mangold, Ravishankar Iyer
arXiv:2511. 15968v2 Announce Type: replace-cross Abstract: External validation of breast ultrasound segmentation models remains limited because internal train--test splits do not capture domain shifts across imaging systems, acquisition protocols, and patient populations.
By Jingru Zhang, Saed Moradi, Ashirbani Saha
arXiv:2510. 17529v3 Announce Type: replace-cross Abstract: Active Surveillance (AS) is a treatment option for managing low and intermediate-risk prostate cancer (PCa), aiming to avoid overtreatment while monitoring disease progression through serial MRI and clinical follow-up.
By Yovin Yahathugoda, Davide Prezzi, Patricia A. Gutierrez, Piyalitt Ittichaiwong, Vicky Goh, Sebastien Ourselin, Michela Antonelli
Medical image classification models are ideally expected to identify diagnostically relevant regions while making predictions, yet standard classification losses rarely provide spatial supervision. Explicit supervision via anatomical shape information, such as segmentation masks of task-relevant anatomy, has been shown to guide the network toward regions relevant to the target prediction.
MDSkin-Net is a multi‑task skin lesion analysis framework that integrates Pattern Analysis priors into a hybrid CNN‑Transformer architecture. It introduces a Pattern Analysis‑Guided Attention Module (PAGAM) with improved Efficient Channel Attention, Multi‑Scale Spatial Attention, and Biased Asymmetry Attention, along with a multi‑scale spatial alignment regularization that uses segmentation masks as soft supervision. Trained only on the ISIC 2017 training split, the model achieves high segmentation and classification performance on multiple datasets, demonstrating strong zero‑shot generalization across different cohorts.
By Yijian Li, Saad Bedros, Paul Bigliardi, Mei Bigliardi Qi, Vassilios Morellas, Nikolaos Papanikolopoulos
arXiv:2607. 17551v1 Announce Type: cross Abstract: Lung ultrasound (LUS) is a bedside tool for assessing pulmonary edema in patients at risk due to heart failure or impaired kidney function.
By Alya Almsouti, Lotfi Mecharbat, Noha Aboukhater, Yousef Alabrach, Siddiq Anwar, Andre Kumar, Ibrahim Almakky, Mohammad Yaqub