The paper introduces a new NILM approach that uses label‑preserving aggregate recomposition and prediction consistency to improve appliance‑level power estimation. By recomposing aggregate windows with only the residual background changed, the method preserves target appliance signals while exposing a new supervisory signal. Experiments on REDD, UK‑DALE, and REFIT show reduced mean absolute error for multiple appliances without adding inference‑time complexity.
By Jiangfeng Liu, Yanfang Fan
The paper introduces FM4NILM, a prompt‑programmable foundation model that estimates the power usage of any requested appliance from whole‑home meter data, a natural‑language description, and optional activation examples. Trained on 645k sequences from seven public datasets, the lightweight transformer achieves competitive performance across twelve appliance requests, outperforming seven appliance‑specific baselines on key metrics such as event F1 and active‑window MAE. The model’s design allows new appliance coverage to be added via prompts and examples rather than building separate specialist networks.
By Xudong Wang, Jiacheng Cui, Junyu Xue, Tongxin Li, Guoming Tang
The paper investigates how the operational value of deep‑learning PV disaggregation depends on deployment regimes—whether the model serves known customers, new customers, future periods, or new regions. Using Ausgrid smart‑meter data and cross‑dataset adaptation to Pecan Street, the authors benchmark several deep sequence architectures and find that deployment regime explains more error variation than model choice. Fine‑tuning on a small number of target‑region households can significantly reduce transfer error, and the benefits of long input windows vary by use case.
By Jack Zheng, Hao Wang
EvoXXLTraffic extends the XXLTraffic traffic‑forecasting benchmark to accommodate sensor‑evolving networks, providing yearly sensor catalogs, persistent station IDs, flow matrices, and geographic graph snapshots across nine California PeMS districts over up to 27 years. The benchmark distinguishes all‑sensor forecasting from supervised adaptation to new sensors, evaluating 13 baseline methods on PEMS04 and PEMS05 and seven methods on the remaining districts, with detailed results on mean MAE for different populations and horizons. The study reports that training on the evolving catalog changes mean MAE on consistently present sensors by less than 1% and highlights that method performance varies by district, evaluation population, horizon, and metric, with no statistically significant seed effects.
By Du Yin, Hao Xue, Arian Prabowo, Shuang Ao, Flora Salim
Ireland’s smart metering programme records electricity use at 30‑minute intervals, which is too coarse to capture domestic appliance use. The authors present a label‑free disaggregation system that splits usage data into nine appliance categories by combining event detection for high‑power loads with questionnaire‑guided estimation. Evaluated on four datasets—including a large Irish smart‑meter dataset of over 4,800 years of use—the hybrid method achieves the lowest whole‑decomposition error and better month‑level performance than two independently developed systems.
By Achal Nanjundamurthy, Rupam Misra, Suzanne Little, Alan F. Smeaton
LoaDiff is a diffusion-based generative model that produces year-long, sub-hourly smart‑meter electricity consumption time series. It can be conditioned on static household attributes like appliance ownership and dynamic factors such as calendar dates and outdoor temperature. Evaluations on three residential datasets show that LoaDiff generates realistic, diverse load profiles, limits memorization, retains useful information for downstream tasks, and responds coherently to conditioning changes.
By Mariia Baranova, Adrien Petralia, Etienne Le Naour, Nathan Etourneau, Guillaume Hofmann, Themis Palpanas
The paper presents a two-part workflow for analyzing smart‑meter data to uncover patterns of residential co‑adoption of photovoltaic (PV) systems and electric vehicles (EVs). First, dynamic time warping k‑means clustering identifies distinct daily import/export archetypes for PV‑only, EV‑only, co‑adopters, and neither groups, revealing a midday‑centered export pattern for many co‑adopters. Second, a bidirectional LSTM model trained on 21‑day windows achieves high detection performance (AUROC 0.991, macro‑F1 0.906) for PV/EV activity, outperforming tabular baselines and remaining robust across labeling rules and temporal splits.
By Jack Zheng, Hao Wang
arXiv:2608. 09255v1 Announce Type: new Abstract: Residential energy estimates are often needed before detailed envelope characteristics, equipment efficiencies, infiltration, sensor, or billing data are available.
By Aditya Ramnarayan, Fatih Evren, Patti Gunderson, Samuel Rosenberg
The study evaluates how well time‑series foundation models (TSFMs) can be adapted for electrical load forecasting. It compares pretrained inference, full fine‑tuning, and low‑rank adaptation (LoRA) across four load aggregation levels, using MOIRAI 1.0 Large as the main backbone and Chronos‑2 as a secondary model. LoRA achieves a 7.5% average NMAE reduction on MOIRAI while updating only about 1% of the parameters, offering a strong accuracy‑efficiency trade‑off, though benefits vary in out‑of‑distribution scenarios.
By Aliullah, Julian Oelhaf, Edouard Fouch\'e, Jessica Deuschel, Christian Bergler, Andreas Maier, Siming Bayer
ElecLoad is a context‑aware agent that improves electricity load forecasting by adaptively organizing the forecasting process around multiple events. It analyzes each event’s relevance, timing, and interactions with historical load, then decides whether to forecast the entire horizon or partition it into segments. Sub‑agents generate initial forecasts for each segment, and the main agent refines them based on feedback, achieving state‑of‑the‑art performance on several datasets.
By Huajian Zhang, Mingyue Cheng, Xingpeng Gao, Xiaoyu Tao, Zhiding Liu, Jiqian Yang, Zhi Li
The paper introduces a data‑onboarding pipeline that detects and repairs defects in building meter data before training machine‑learning demand‑forecasting models. Controlled experiments on hourly electricity data from twelve U.S. buildings show that the pipeline restores forecast accuracy to clean‑data levels, even when defects affect up to 1.6% of training rows, and works across multiple models and horizons. The study also documents a first‑version over‑cleaning issue, its cause, and a per‑building calibration that corrects it, with all results reproducible from publicly pinned inputs.
By Yixuan Liang
arXiv:2601.17990v2 Announce Type: replace-cross
Abstract: Shaping multi-megawatt flexible loads such as data centers alters generator dispatch on the electric grid, affecting system-wide CO2 emission...
By Bokan Chen, Raiden Hasegawa, Adriaan Hilbers, Ross Koningstein, Ana Radovanovi\'c, Utkarsh Shah, Gabriela Volpato, Mohamed Ahmed, Tim Cary, Rod Frowd