arXiv:2605.23194v2 Announce Type: replace-cross
Abstract: Fast and reliable optimal power flow (OPF) approximation is important for power system operation, yet heterogeneous OPF graph models are ofte...
By Massimiliano Lupo Pasini, Yijiang Li, Kibaek Kim, Teja Kuruganti
arXiv:2602. 17975v2 Announce Type: replace Abstract: This work formulates and solves optimization problems to generate input points that yield high errors between a neural network's predicted AC power flow solution and solutions to the AC power flow equations.
By Robert Parker
arXiv:2607. 13763v1 Announce Type: cross Abstract: Single-task fine-tuning of graph neural networks (GNNs) for power grid problems exhibits a systematic failure mode: models that achieve the lowest in-distribution error degrade the most under topology shift.
By Charilaos Papaioannou, Ioannis Tsantilas, Dimitris Giannakakos, Vasilis Michalakopoulos, Sotiris Pelekis, Vangelis Marinakis, Arsam Aryandoust, Antonello Monti, Ricardo J. Bessa, Perdo P. Vergara, Jochen Cremer, Elissaios Sarmas
arXiv:2608. 16494v1 Announce Type: cross Abstract: Modern power systems face growing operational complexity driven by the integration of renewable energy sources, decentralization, and the need for real-time decision-making across a wide range of timescales.
By Martin Sadric, Sebastian P\"utz, Christian Nauck, Veit Hagenmeyer, Frank Hellmann, Dirk Witthaut, Benjamin Sch\"afer
Single-task fine-tuning of graph neural networks (GNNs) for power grid problems exhibits a systematic failure mode: models that achieve the lowest in-distribution error degrade the most under topology shift. We term this topology overfitting: the tendency of task-specific gradient signals to encode relational structure particular to the training topologies rather than the underlying physics, causing models to fail on unseen grids despite strong in-distribution performance.
arXiv:2410. 04818v2 Announce Type: replace-cross Abstract: We present PINCO, an unsupervised learning framework that integrates Graph Neural Networks with physics-informed neural networks for AC optimal power flow (AC-OPF) solutions.
By Anna Varbella, Damien Briens, Blazhe Gjorgiev, Giuseppe Alessio D'Inverno, Priya L. Donti, Giovanni Sansavini
arXiv:2609.16738v1 Announce Type: cross
Abstract: Power Flow (PF), Optimal Power Flow (OPF), and State Estimation (SE) are fundamental problems in power system analysis, but solving them is computati...
By Ferran Bohigas-Daranas, Hamid Latif-Mart\'inez, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt, Pere Barlet-Ros
arXiv:2604.22784v2 Announce Type: replace
Abstract: Power System State Estimation (PSSE) converts geographically distributed measurements into the voltage magnitudes and phase angles needed for grid...
By Solon Falas, Markos Asprou, Charalambos Konstantinou, Maria K. Michael
arXiv:2606. 03125v1 Announce Type: new Abstract: Deep learning proxies for Alternating Current Optimal Power Flow (ACOPF) lack systematic methods for determining architectural size.
By Dhruvi Khandelwal, Anurag Basistha, Ayushi Jolotia, Parikshit Pareek
The paper introduces Multi-Channel Physics-Aware Random Walk Fingerprints (MC-PA-RWF), a lightweight graph-level representation that incorporates physical edge states into random-walk propagation for power grid graphs. By constructing multiple edge-weighted channels from domain-relevant attributes and concatenating channel-specific fingerprints, the method achieves high balanced accuracy on PowerGraph benchmarks, outperforming topology-only RWF and matching or surpassing several graph neural network baselines. Experiments on three benchmark systems show statistically significant improvements, with the node-edge extension reaching up to 99.32% balanced accuracy and boosting failure-class F1 scores by 1.60–5.84 percentage points.
By Adnan Anwar
arXiv:2510. 22048v4 Announce Type: replace Abstract: Power flow (PF) calculations are the backbone of real-time grid operations, across workflows such as contingency analysis (where repeated PF evaluations assess grid security under outages) and topology optimization (which involves PF-based searches over combinatorially large action spaces).
By Ana K. Rivera, Anvita Bhagavathula, Alvaro Carbonero, Priya Donti
EvEMTBench is an open, executable, and versioned benchmark designed to standardize the evaluation of machine‑learning methods for power system protection. It defines 12 protection and event‑analysis functions across four grids (20–345 kV) as 24 scored tasks, enabling structured assessment under varied observability, distribution shifts, and cross‑grid transfer scenarios. The benchmark includes committed data partitions, leakage controls, and reproducible reporting, and demonstrates that wider observability does not always help, that shifted conditions expose hidden failures, and that fault detection transfers better than fault localization.
By Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer