BRIDGE-EEG is an efficient multi‑task EEG classification pipeline that leverages self‑supervised pretraining while dramatically reducing model size. It maps heterogeneous EEG recordings to a unified 62‑channel time‑frequency representation, pretrains an SE‑ResNet18 teacher with SimCLR, and distills it into smaller SE‑ResNet8 and SE‑ResNet4 students. The compact models achieve accuracy comparable to or better than larger foundation models on abnormality detection and emotion recognition, and they consume up to three times less energy on edge devices, enabling deployment on wearable hardware.
By Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
ThinkNet is a validation‑controlled framework that uses train‑only normalization, evolutionary search guided by validation, and validation‑gated inference to build compact motor‑imagery EEG decoders that generalize to unseen subjects. In a fixed benchmark on the BCI Competition IV‑2a dataset, the best single model achieved 44.35 % accuracy with only 4.9 k parameters, while a compact ensemble of six families reached 43.31 % accuracy. Across a broader search, models with ≤25 k parameters outperformed larger ones after retraining, but validation reliability remains a bottleneck under subject shift.
By Abdul Basit, Saim Rehman, Muhammad Shafique
EEG-AS is an instance-level algorithm selection framework designed for EEG foundation models. It characterizes each EEG instance using latent embeddings, handcrafted neurophysiological features, and an anchor foundation model, then learns to reconstruct the behaviors of other foundation models from privileged prediction tokens. During inference, EEG-AS estimates these behaviors without running the full model portfolio, enabling efficient selection among seven EEG foundation models and significantly reducing the performance gap between the single best solver and the oracle upper bound across seven public EEG benchmarks.
By Yunzhen Zhang, Ruoxi Piao, Hasan Onur Keles, Mustafa Misir
arXiv:2609.23924v1 Announce Type: new
Abstract: Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree ab...
By Kevin Zhou, Sparsh Roy
arXiv:2606. 09189v1 Announce Type: cross Abstract: EEG foundation-model releases are usually audited one endpoint at a time: raw-reconstruction, membership inference, identity linkage, or DP-SGD on the downstream head.
By Jianwei Tai
EEG foundation-model releases are usually audited one endpoint at a time: raw-reconstruction, membership inference, identity linkage, or DP-SGD on the downstream head. We audit the same released embeddings under all four endpoints jointly, on BIOT, LaBraM, and EEGPT, and show that each single-endpoint audit clears releases that still leak spectral attributes.
OneEEG is a unified signal‑visual multimodal language model designed for multi‑task EEG understanding. It jointly learns from numerical EEG data and visual EEG renderings, employing a task‑aware Mixture of Projectors to align diverse EEG features with a large language model’s embedding space. The authors introduce the OneEEG‑Instruct dataset for instruction tuning and the OneEEG‑Bench benchmark to evaluate performance, demonstrating that existing multimodal LLMs struggle with EEG inputs while OneEEG outperforms them across various tasks.
By Jiacheng Zhang, Xueyi Zhang, Xin Lu, Siqi Cai, Haizhou Li
The paper introduces GRAFT-EEG, a method that removes the active‑set common‑reference gauge and transports each native EEG mask through a template motor leadfield, enabling target‑statistics‑blind transfer for cross‑dataset motor‑imagery decoding. Using a source‑fitted spectral classifier and a bounded state‑space‑model residual, the approach achieves higher balanced accuracy (60.865%) than a strict‑clean baseline (52.684%) across five leave‑one‑dataset‑out targets, and outperforms several control conditions in post‑hoc tests. The study also reports positive results in a separate 60‑participant same‑paradigm evaluation, though the dynamic‑static comparison was inconclusive.
"whyItMatters":"The method demonstrates that accounting for observation‑operator changes can substantially improve cross‑dataset EEG decoding performance, offering a more robust approach for motor‑imagery applications."
By Ying Zhou, Mengting Liu
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
arXiv:2607. 27274v1 Announce Type: new Abstract: EEG-based disease diagnosis requires one prediction per subject, yet common pipelines segment recordings into short instances, inherit the subject label for every instance, and train instance-level classifiers.
By Zhiyuan Ma, Zeyuan Li, Zhiyi Lu, Jiacheng Hao, Youlang Du, Zhen Jiang, Xinche Zhang, Yuhao Sun, Sen Song
EEGProbe is a new benchmark that tests whether general-purpose vision‑language models can understand minimally processed, channel‑wise EEG signals without task‑specific engineering. It contains 620 EEG‑centered questions across 13 subtasks grouped into EEG Signal Classification, EEG Cross‑modal Alignment, and EEG Neurophysiological Reasoning, and it preserves temporal structure to avoid shortcut answers. Eleven VLMs were evaluated in a zero‑shot protocol, with the best model scoring only 41.63 % and cross‑modal alignment identified as a major bottleneck; the benchmark also explores how temporal, spectral, spatial, and physiological EEG features influence model performance and offers neurophysiological guidance to improve predictions.
AutoBCI is an agentic framework that discovers and selects EEG decoding architectures across diverse tasks such as emotion recognition, motor imagery, and sleep staging. It employs a Designer Agent that performs Pool‑Guided Architecture Discovery (PGAD) and a Forecaster Agent that uses Performance Estimation from Early Knowledge (PEEK) to predict full‑budget validation performance from early learning curves. Evaluated on 14 EEG datasets with six large language models, AutoBCI’s best architecture (Claude Opus 5.5) achieves 64.16% average test balanced accuracy, slightly surpassing the strongest baseline, and PEEK reduces prediction error by 38.1% compared to the best‑observed‑score baseline.
By Muyun Jiang, Yi Ding, Wei Zhang, Jinbo Chen, Chenyu Liu, Zhenjie Yang, Yuxin Li, Jingyuan Chen, Yuhao Lu, Yong Li, Shuailei Zhang, Cuntai Guan