arXiv:2606. 11556v1 Announce Type: cross Abstract: Continuous electrocardiography (ECG) monitoring could surface rhythm abnormalities before they escalate into cardiovascular events.
By Kaan Arda Akyol, Jakub Kacper Szel\k{a}g, Aydin Abadi, Maha Alghamdi, Ghadah Albalawi, Ghouse Ibrahim Kaleelullah, Hilal Tutus, Sarah Al Subaiei, Shardul Kapse, Syed Mohammed Raheeb, Mujeeb Ahmed, Rehmat Ullah
arXiv:2608. 05893v1 Announce Type: new Abstract: Electrocardiography (ECG) is one of the most widely used non-invasive tools for diagnosing cardiovascular disease, but transforming multi-lead ECG recordings into reliable clinical reports remains challenging.
By Akanta Das, Tasinul Islam Ahon, Ahmed Mahir Sultan Rumi, Md Mahbubur Rahman, Tausif Amim Shadly, Tanzima Hashem
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.
By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
arXiv:2605. 29977v2 Announce Type: replace-cross Abstract: High-fidelity ECG interpretation is increasingly reliant on massive foundation models, yet their deployment in clinical edge-care remains hindered by extreme computational demands.
By Dang Nguyen Hong, Nhi Ngoc-Yen Nguyen, Huy-Hieu Pham
The paper introduces representative‑morphology heatmaps, a deterministic ECG‑to‑image representation that averages the five beats closest to the block mean within each ten‑beat block, producing either a conventional trace or a dense cardiac‑time‑by‑lead heatmap. Experiments on PTB, ECG‑ID, and MIMIC‑IV‑ECG‑DEMO show that heatmaps consistently improve verification and identification performance across 15 compact models, reducing EER by an average of 9.59 percentage points and increasing Rank‑1 by 24.69 points. The study also demonstrates that ImageNet initialization benefits multilead datasets, that performance does not scale monotonically with model size, and that useful channel combinations vary by cohort and biometric task.
By Athanasios Angelakis, Marta Gomez-Barrero
Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-mor...
arXiv:2608. 03597v1 Announce Type: new Abstract: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and is associated with increased risks of stroke, heart failure, and mortality.
By Amirhossein Taleshinosrati, Yangyang Wang, Atitaya Phoemsuk, Vahid Abolghasemi, Naser Hossein Motlagh, Sadasivan Puthusserypady, Daniel Teichmann, Abdolrahman Peimankar
arXiv:2608. 09053v1 Announce Type: cross Abstract: Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence.
By Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai, Xingyao Wang, Chenxi Yang, Jianqing Li, Chengyu Liu
arXiv:2607. 24035v1 Announce Type: cross Abstract: Explainable AI (XAI) is used to assess whether artificial intelligence models rely on meaningful patterns, yet explanations that appear plausible for individual predictions may systematically misrepresent model behavior.
By Nils Gumpfer, Michael Guckert, Samuel Sossalla, Birgit A{\ss}mus, Jennifer Hannig
arXiv:2607. 27404v1 Announce Type: new Abstract: Existing benchmarks for electrocardiogram foundation models primarily evaluate downstream predictive performance, providing limited insight into whether their internal representations can be faithfully decomposed, clinically interpreted, or reproduced across independent analyses.
By Yixuan Duan, Wei Qiu
ECGQuest is a new benchmark that evaluates language models on the contextual knowledge required for electrocardiogram interpretation, featuring 10,904 True/False questions derived from 23 ECG references and 2003‑2025 Computing in Cardiology proceedings. The study tested 23 commercial and open‑source models, finding that zero‑shot accuracy ranged from 49.5% to 74.4% and that fine‑tuning with Low‑Rank Adaptation improved all open‑source models by 6.5–14.1%, with the best fine‑tuned model achieving 76.3% accuracy and a five‑model ensemble reaching 78.5%. ECGQuest demonstrates that parameter‑efficient fine‑tuning can enable smaller models to compete with larger commercial ones on ECG‑specific tasks.
By Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni