arXiv:2601. 07556v2 Announce Type: replace-cross Abstract: Electroencephalogram (EEG)-based brain-computer interfaces (BCIs) face significant deployment challenges due to inter-subject variability, signal non-stationarity, and computational constraints.
By Siyang Li, Jiayi Ouyang, Zhenyao Cui, Ziwei Wang, Tianwang Jia, Feng Wan, Dongrui Wu
Functional near-infrared spectroscopy (fNIRS) provides portable and spatially localized measurements of cortical hemodynamics, but differences in channel count, probe layout, signal distribution, and...
arXiv:2608. 00048v1 Announce Type: cross Abstract: Electroencephalography (EEG) generation is essential for alleviating data scarcity and enabling large scale neural modeling in brain computer interface applications.
By Boheng Liu, Ziyu Li, Chenghua Duan, Qing Li, Xia Wu
The paper introduces MOPC, a memory‑augmented online test‑time adaptation framework for EEG motor‑imagery BCIs that operates without source data. It uses random‑mask perturbations to enforce prediction consistency, a confidence‑calibrated reweighting loss to handle pseudolabels and class imbalance, and a lightweight memory module to prevent catastrophic forgetting. Evaluated on BCI IV IIb and OpenBMI datasets, MOPC outperforms prior methods by 2.22% and 3.67% while maintaining per‑trial adaptation latency of 40–60 ms.
By Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou
arXiv:2608.03176v2 Announce Type: replace
Abstract: Imagined handwriting offers a temporally rich paradigm for non-invasive neural decoding, yet reliable recognition across unseen participants remain...
By Xiao Fan, Hongbin Guo, Yubo Han, Yi Zhang
EEGProbe is a new benchmark that tests whether general-purpose vision‑language models can understand minimally processed, channel‑wise EEG signals without task‑specific engineering. It contains 620 EEG‑centered questions across 13 subtasks grouped into EEG Signal Classification, EEG Cross‑modal Alignment, and EEG Neurophysiological Reasoning, and it preserves temporal structure to avoid shortcut answers. Eleven VLMs were evaluated in a zero‑shot protocol, with the best model scoring only 41.63 % and cross‑modal alignment identified as a major bottleneck; the benchmark also explores how temporal, spectral, spatial, and physiological EEG features influence model performance and offers neurophysiological guidance to improve predictions.
arXiv:2607. 21384v1 Announce Type: new Abstract: Electroencephalography (EEG) models used for epilepsy are often limited to specific datasets and tasks.
By Targol Bakhtiarvand, Jugal Kalita, Adham Atyabi
arXiv:2503. 02636v5 Announce Type: replace-cross Abstract: Resting-state EEG provides a non-invasive view of spontaneous brain activity, but extracting meaningful patterns is often limited by scarce high-quality data and reliance on manually engineered features.
By Yeganeh Farahzadi, Morteza Ansarinia, Zoltan Kekecs
arXiv:2605. 29263v2 Announce Type: replace Abstract: Low-channel wearable electroencephalography (EEG) is attractive for long-term monitoring, but four frontal electrodes provide only a sparse and spatially biased view of distributed scalp activity.
By Minghao Xiao
BRIDGE-EEG is an efficient multi‑task EEG classification pipeline that leverages self‑supervised pretraining while dramatically reducing model size. It maps heterogeneous EEG recordings to a unified 62‑channel time‑frequency representation, pretrains an SE‑ResNet18 teacher with SimCLR, and distills it into smaller SE‑ResNet8 and SE‑ResNet4 students. The compact models achieve accuracy comparable to or better than larger foundation models on abnormality detection and emotion recognition, and they consume up to three times less energy on edge devices, enabling deployment on wearable hardware.
By Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
arXiv:2607. 11530v1 Announce Type: new Abstract: Decoding continuous three-dimensional (3D) motor imagery (MI) using non-invasive electroencephalography (EEG)-based brain--computer interfaces (BCIs) remains challenging due to signal variability and residual decoding errors.
By Jiamian Li, Niall McShane, Attila Korik, Naomi du Bois, Karl McCreadie, Leen Jabban, Benjamin Metcalfe, \"Ozg\"ur \c{S}im\c{s}ek, Damien Coyle