arXiv AI

Selection of Heart Sound Segments for Synchronous Classification of Multi-channel Heart Sounds

arXiv AI
Nov 5

ENACT-Heart -- ENsemble-based Assessment Using CNN and Transformer on Heart Sounds

ENACT-Heart is a two‑branch ensemble model for classifying heart sounds, combining a Vision Transformer that processes spectrogram images with a convolutional neural network that analyzes waveform visualizations and spectral centroids from the same recordings. The predictions from both branches are fused using a weighted average with fixed, input‑independent weights. On the PASCAL heart‑sound dataset, the ensemble achieved 97.52% accuracy, outperforming the individual ViT (93.88%) and CNN (95.45%) branches, and also delivered a macro‑F1 of 0.94 and a recall of 0.74 for extra heart sounds.

By Jiho Han, Adnan Shaout
arXiv Computer Vision
6d ago

Strong Fused Performance Can Mask Branch Collapse in a Dual-View Heart-Sound Classifier: A Three-Part Diagnostic Protocol

Fusion models are often evaluated solely on their combined score, assuming each branch contributes meaningfully. In a dual‑view heart‑sound classifier (AudioFuse), the spectrogram branch is effectively unused despite strong fused performance, a phenomenon termed branch collapse. The authors propose a three‑part diagnostic—branch deletion impact, linear probing versus an untrained copy, and single‑branch training—to detect such collapse, and find that while the branch can learn its view alone, it is ignored when jointly trained, likely due to early optimisation imbalance.

By Safayet Khan, Hasan Zohirul Islam, Md. Tauhid Bin Iqbal
arXiv AI
Sep 10

AudioFuse: Unified Spectral-Temporal Learning via a Hybrid ViT-1D CNN Architecture for Robust Phonocardiogram Classification

AudioFuse is a hybrid architecture that jointly learns from spectrograms and raw waveforms to classify phonocardiograms. It combines a wide-and-shallow Vision Transformer for spectral features with a shallow 1D CNN for temporal waveforms, reducing overfitting while capturing complementary information. On the PhysioNet 2016 dataset, AudioFuse achieves a state‑of‑the‑art ROC‑AUC of 0.8608 and shows superior robustness to domain shift on the PASCAL dataset, outperforming both spectrogram‑only and waveform‑only baselines.

By Md. Saiful Bari Siddiqui, Utsab Saha
arXiv Computation and Language
Nov 4

ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals

ARTA is a graph‑based combinatorial framework that improves interbeat interval estimation from wearable ECG by integrating candidates from multiple detectors into a directed acyclic graph. It uses detector agreement, ECG quality, and history‑dependent transition costs to select a coherent heartbeat sequence via beam‑search dynamic programming, effectively suppressing false detections and recovering missed beats. On benchmark datasets, ARTA reduces heart‑rate mean absolute error by 54% compared to the best single detector and achieves high accuracy in R‑peak detection and IBI estimation while remaining lightweight and training‑free.

By Shovito Barua Soumma, Asiful Arefeen, Hassan Ghasemzadeh
arXiv AI
Oct 27

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

The study compares classical and deep learning classifiers for a five‑class respiratory‑sound dataset of 1,211 clips. An SVM using 30 summary features (MFCC, ZCR, RMS) achieves macro recall of 0.78, while a 1.13M‑parameter convolutional‑recurrent network reaches 0.75–0.77; no clear advantage is found between model families. The largest performance gain comes from standardizing the SVM’s features, which boosts macro recall by 27 points, far exceeding any architectural difference.

By Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
arXiv Machine Learning
Aug 4

Automated ECG Interval Measurement and Wave Delineation Using Fast Fourier Convolution ResNet

arXiv:2608. 00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts.

By Farhan Adam Mukadam, Harshit Mishra, Nachiket Makwana, Pradyot Tiwari, Subramani Kandasamy, KVS Hari
arXiv Machine Learning
5d ago

RespCCT and FreqCCT: Compact, Explainable and Cost-Aware Convolutional Transformers for Multi-Class Respiratory Disease Classification

RespCCT and FreqCCT are compact convolutional transformer models designed for multi‑class respiratory disease classification from chest auscultation recordings. Trained from scratch on mel, constant‑Q, and cepstral images of 5‑second audio frames, they achieve high accuracy (98.13% and 97.58% respectively) while using far fewer parameters than large pretrained networks. The study also evaluates computational cost per pipeline stage, examines attribution map consistency, and demonstrates that a linear probe can identify the recording source with 95.8% accuracy.

By Auntor Chakma, Mst. Farhana Akter, Abu Henaf Rashid Ahmad Mufti, Asmana Yasmin
arXiv AI
Sep 21

BEAT-Net: Injecting Biomimetic Spatio-Temporal Priors for Interpretable ECG Diagnosis

BEAT-Net is a supervised biomimetic framework for ECG diagnosis that incorporates QRS-centered tokenization and a hierarchical architecture mirroring a cardiologist’s workflow. It processes heartbeat sequences through morphological, spatial, temporal, and transformer-based stages, achieving an AUC of 0.924 on large benchmarks while using only 0.7 million parameters. The model outperforms the 39.5‑million‑parameter HeartLang foundation model on morphological form classification and demonstrates superior cross‑dataset generalization with only 35% of the training data.

By Runze Ma, Haonan Lyu, Shunbo Jia, Qiang Yang, Muzi Xu, Jiaqi Zhang, Zihe Luo, Caizhi Liao