arXiv:2606. 12378v1 Announce Type: cross Abstract: Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments.
By Zhi Wei Xu, Torbj\"orn E. M. Nordling
arXiv:2609.10303v1 Announce Type: new
Abstract: Face recognition (FR) is a widely used modality for biometric authentication, but conventional models rely on visible-spectrum imagery and degrade when...
By Anjith George, Adam Unal, Sebastien Marcel
EgoHRV is a method that estimates heart rate variability (HRV) and heart rate (HR) from the gaze cameras in egocentric headsets. It uses a 3D backbone and a low–high decomposition module to extract the blood volume pulse signal from gaze video, and aligns frequency‑domain representations of contact‑based and camera‑derived signals through cross‑domain pretraining. The approach achieves state‑of‑the‑art accuracy for HR and HRV estimation and, when integrated into EgoExo4D’s proficiency estimator, improves accuracy by 17.8%.
arXiv:2607. 06598v1 Announce Type: cross Abstract: Heart rate measurement is one of the key requirements for real-time health monitoring, in particular for health caring of elderly people.
By Kelly Li, Fulu Li
The paper introduces Heartian, a physiology‑aware framework that augments Gaussian head avatars with cardiac‑cycle‑dependent albedo modulation, enabling the encoding of remote photoplethysmography (rPPG) signals. By supervising with synchronized contact PPG, the method models the cardiac waveform as a sum of two Gaussians and learns per‑frame spatial residuals via a lightweight MLP. Experiments on 152 stationary recordings from UBFC‑rPPG, PURE, and MMPD show heart‑rate estimation errors as low as 0.29 bpm MAE and 0.38 % MAPE, while preserving reconstruction quality with negligible PSNR loss.
By Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Ak\c{s}it
The paper introduces the Columbia University Palm‑vein (CUP) dataset, the first public video‑based palm‑vein dataset that captures palms under four surface conditions—clean, warm, wet, and dirty—along with physiological and demographic metadata. Twenty‑one recognizers are benchmarked on CUP, revealing that models performing well on clean palms lose most accuracy on dirty palms, with mean EER roughly quadrupling. The authors propose a lightweight design that fuses global cosine similarity with a saliency‑steered region‑level optimal transport, achieving state‑of‑the‑art performance across all surfaces while reducing parameters and computational cost, and they identify demographic gaps in warm‑condition performance.
By Xiaofeng Yan, Kechen Liu, Abhilash Venkatesh, Cathy Zhang, Xia Zhou, Salvatore Stolfo
arXiv:2609.36607v1 Announce Type: new
Abstract: Remote photoplethysmography (rPPG) offers a promising non-contact solution for heart rate monitoring, yet its real-world robustness is fundamentally li...
By Jieying Wang, Xinqi Cai, Caifeng Shan, Wenjin Wang
Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose $\unicode{x1F493}$Heartian, a physiology-aware...
arXiv:2503. 07825v3 Announce Type: replace-cross Abstract: We present an advance in wearable technology: a mobile-optimized, real-time, ultra-low-power event camera system that enables natural hand gesture control for smart glasses, dramatically improving user experience.
By Prarthana Bhattacharyya, Joshua Mitton, Ryan Page, Owen Morgan, Oliver Powell, Benjamin Menzies, Gabriel Homewood, Kemi Jacobs, Paolo Baesso, Taru Muhonen, Richard Vigars, Louis Berridge
arXiv:2607. 05230v1 Announce Type: new Abstract: Pre-term infants are susceptible to potentially harmful apnoea-related cessations of breathing due to immature respiratory control.
By Dineo Serame, Lionel Tarassenko, Mauricio Villarroel
The paper introduces representative‑morphology heatmaps, a deterministic ECG‑to‑image representation that averages the five beats closest to the block mean within each ten‑beat block, producing either a conventional trace or a dense cardiac‑time‑by‑lead heatmap. Experiments on PTB, ECG‑ID, and MIMIC‑IV‑ECG‑DEMO show that heatmaps consistently improve verification and identification performance across 15 compact models, reducing EER by an average of 9.59 percentage points and increasing Rank‑1 by 24.69 points. The study also demonstrates that ImageNet initialization benefits multilead datasets, that performance does not scale monotonically with model size, and that useful channel combinations vary by cohort and biometric task.
By Athanasios Angelakis, Marta Gomez-Barrero
Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-mor...