The rapid advancement of foundation models has transformed computer vision, yet their adaptation to medical imaging, particularly purpose built foundation models for spatio temporal echocardiography v...
arXiv:2606. 17437v1 Announce Type: cross Abstract: Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges.
By Bo Gou, Jicheng Zhang, Jianlong Xiong, Tao He, Bentian Liu, Hai Wu, Yijiao Wang, Yu Zhang, Yujia Yang, Yun Dai, Jian Liu, Jie Wang
arXiv:2610.05603v2 Announce Type: replace
Abstract: Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, lo...
By Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen, Devika Subramanian
The paper introduces the first publicly available dataset for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography, comprising over 25,000 labeled videos generated through a novel data‑generation strategy that correlates clinical notes with echocardiographic videos. Using this dataset, the authors train a reproducible PLAX‑EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that combining PLAX and A4C predictions via simple late fusion reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and they release the dataset, models, and demos for community use.
The paper introduces the first publicly available dataset of over 25,000 parasternal long‑axis (PLAX) echocardiography videos labeled for left ventricular ejection fraction (EF), created through a novel data‑generation strategy that links clinical notes to video data. Using this dataset, the authors train a reproducible PLAX‑based EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that simple late fusion of PLAX and A4C predictions reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and release the dataset, models, and demos publicly.
By Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
arXiv:2608.30975v1 Announce Type: cross
Abstract: Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep lea...
By Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
Echo-E$^3$Net is an anatomy‑guided spatio‑temporal neural network designed to estimate left ventricular ejection fraction (LVEF) from ultrasound images. It uses a dual‑phase Endocardial Border Detector to locate end‑diastole and end‑systole landmarks and an Endocardial Feature Aggregator to fuse these landmarks with global deep‑feature descriptors for EF regression. The model achieves competitive accuracy on EchoNet‑Dynamic and EchoNet‑Pediatric datasets while using only 1.55 M parameters and 8.05 GFLOPs, enabling real‑time deployment on limited‑resource devices.
By Moein Heidari, Afshin Bozorgpour, AmirHossein Zarif-Fakharnia, Wenjin Chen, Dorit Merhof, David J. Foran, Jasmine Grewal, Ilker Hacihaliloglu
arXiv:2610.08109v1 Announce Type: new
Abstract: Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while prese...
By Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
The paper introduces a two-stage AI framework that synthesizes realistic, multi-view echocardiographic sequences from dynamic whole-heart meshes. Stage 1 uses an unpaired GAN‑diffusion model to convert extracted cross‑sections into ultrasound‑like frames, while Stage 2 applies masked video reconstruction to enhance temporal coherence and cardiac motion. Evaluation shows that the combined approach yields high realism at the frame level and significantly improves video‑level motion quality and consistency, offering a scalable source of annotated data for augmenting datasets and developing multi‑view cardiac assessment methods.
By Jo\~ao Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge, Sandro Queir\'os
arXiv:2403.19880v2 Announce Type: replace-cross
Abstract: Purpose: Large labeled echocardiography datasets are costly to collect. We use diffusion models to generate synthetic training data for segme...
By Milad Yazdani, Pooria Ashrafian, Moein Heidari, Alireza Rafiei Sardouei, Dena Shahriari, Ilker Hacihaliloglu
The paper introduces ORBIT, a self‑supervised method for detecting end‑diastolic and end‑systolic cardiac phases in fetal echocardiography without manual annotations. ORBIT learns a latent motion trajectory through registration, enabling orientation‑robust identification of phase transitions across diverse fetal heart positions. Evaluated on normal and congenital heart disease cases, it achieves low mean absolute errors (≈1.9–2.4 frames) and outperforms prior annotation‑free approaches that assume fixed orientations.
By Yingyu Yang, Qianye Yang, Can Peng, Elena D'Alberti, Olga Patey, Aris T. Papageorghiou, J. Alison Noble
The paper introduces SV-Cine, a cardiac MRI segmentation framework tailored for single ventricle physiology (SVP). It combines a generative data augmentation pipeline that creates synthetic 3D cardiac meshes and MRI, with a diagnosis-conditioned adaptation of the CineMA foundation model that uses patient-level diagnostic information to improve segmentation. Evaluations on an internal cohort show high Dice scores for left and right ventricles, outperforming nnU-Net, and demonstrate that incorporating diagnosis priors can adapt a pretrained model to specialized SVP tasks.
By Lila Cunge, Yuehong Liu, Hang Xu, Thomas Coudert, Pierangelo Renella, J Paul Finn, William Hsu, Kim-Lien Nguyen