arXiv:2506. 02260v5 Announce Type: replace-cross Abstract: Wearable devices enable continuous multi-modal physiological and behavioral monitoring, yet analysis of these data streams faces fundamental challenges including the lack of gold-standard labels and incomplete sensor data.
By Howon Ryu, Yuliang Chen, Yacun Wang, Andrea Z. LaCroix, Chongzhi Di, Loki Natarajan, Yu Wang, Jingjing Zou
arXiv:2608. 07385v1 Announce Type: cross Abstract: Learning disentangled representations is a key requirement for developing versatile, general-purpose, and sustainable models in multi-modal wearable computing.
By Ioannis Ziogas, Ensieh Khazaei, Bilal Taha, Aamna Al Shehhi, Ahsan H. Khandoker, Leontios J. Hadjileontiadis, Dimitrios Hatzinakos
arXiv:2607. 27635v1 Announce Type: cross Abstract: Wearable sensors continuously capture fine-grained multivariate time-series data, providing opportunities to model behavioural patterns associated with health outcomes.
By Xiaotong Yu, Joshua Y. Kim, HaeJin Lee, Kalina Yacef
arXiv:2606. 27886v1 Announce Type: new Abstract: Recent advances in Human Activity Recognition (HAR) from wearable sensors have shown that multi-modal deep learning models consistently outperform their uni-modal counterparts.
By Ahmed Mohamady, Robin Burchard, Kristof Van Laerhoven
CIG-MAE is a self‑supervised framework for WiFi‑based human action recognition that uses a cross‑modal masked autoencoder to reconstruct both amplitude and phase of Channel State Information. It introduces an adaptive, information‑guided masking strategy that focuses on high‑density time‑frequency regions and employs a Barlow Twins regularizer to align cross‑modal representations without negative samples. Experiments on three public datasets show that CIG‑MAE outperforms state‑of‑the‑art SSL methods and even surpasses a fully supervised baseline, highlighting its data efficiency, robustness, and generalization.
By Gang Liu, Yanling Hao, Yixuan Zou
The paper introduces a new evaluation protocol for deep multivariate imputation models on wearable device data, addressing the issue of structured missingness where sensor features drop out together. Using a Garmin smartwatch dataset from an epilepsy patient, the authors generate realistic block-missing patterns from training data and show that matching the training protocol to this distribution reduces BRITS’ mean absolute error by 43%. They also extend BRITS with time‑of‑day encoding and compare it to linear interpolation and SAITS, finding that no single model dominates and that model rankings vary with evaluation design.
By Skye Goodman, Roussel Desmond Nzoyem, Leandro Junges, Peter Kissack, Yasser Qureshi, Amberly Brigden, Jeff Clark, Nawid Keshtmand
arXiv:2605. 22759v2 Announce Type: replace Abstract: While ubiquitous wearable sensors capture a wealth of behavioral and physiological information, effectively transforming these signals into personalized health insights is challenging.
By Girish Narayanswamy, Maxwell A. Xu, A. Ali Heydari, Samy Abdel-Ghaffar, Marius Guerard, Kara Vaillancourt, Zhihan Zhang, Jake Garrison, Levi Albuquerque, Dimitris Spathis, Hong Yu, Hamid Palangi, Xuhai "Orson" Xu, David G. T. Barrett, Joseph Breda, Jed McGiffin, Yubin Kim, Yuwei Zhang, Naghmeh Rezaei, Samuel Solomon, Karan Ahuja, Tim Althoff, Jake Sunshine, Ming-Zher Poh, Benjamin Yetton, Ari Winbush, Nicholas B. Allen, James M. Rehg, Isaac Galatzer-Levy, Yun Liu, John Hernandez, Anupam Pathak, Conor Heneghan, Yuzhe Yang, Ahmed A. Metwally, Pushmeet Kohli, Mark Malhotra, Shwetak Patel, Xin Liu, Daniel McDuff
Hypnos is a multi‑modal sleep foundation model that learns generalisable representations of physiological signals by predicting the next token across eight sensing modalities (EEG, ECG, respiratory, etc.) using an auto‑regressive RQ‑Transformer. Trained on over 20,000 overnight polysomnography recordings, it outperforms existing foundation models on most benchmarks, matching strong supervised baselines for sleep‑stage classification while requiring 100× less labelled data. Additionally, Hypnos generalises beyond sleep, surpassing a dedicated ECG model in atrial fibrillation detection.
By Jonathan F. Carter, Lionel Tarassenko
Time-series foundation models have demonstrated strong cross-domain transfer, yet their common architectural assumptions remain poorly aligned with wearable physiological signals, which are multichann...
SOTER is a generative foundation model designed for wearable physiological time‑series data. It integrates cross‑channel coupling, spectrum‑guided expert specialization, and continuous‑time latent evolution, using a spatial feature‑aware backbone, a PSD‑guided mixture‑of‑experts layer, and a neural controlled differential equation decoder. Trained on 226 billion time points from five public datasets, SOTER outperforms baselines in zero‑shot forecasting, classification, and imputation across six benchmarks, and remains robust to additive noise.
By Fangke Chen, Sirry Chen, Wei Chen, Zhongyu Wei
arXiv:2606. 09605v1 Announce Type: new Abstract: Foundation models offer a promising route to compress multi-modal physiological signals into compact representations of human health, with broad applications across sleep medicine, cardiology, neurology and other healthcare domains.
By Jonathan F. Carter, Lionel Tarassenko
arXiv:2610.19411v1 Announce Type: new
Abstract: A major challenge in wearable device activity recognition is the heterogeneity across datasets in sensor placement, channel count, sampling rate and su...
By Yogesh Prabhu, Loki Natarajan, Jingjing Zou