arXiv:2606. 24394v1 Announce Type: cross Abstract: Electroencephalography (EEG) is the dominant non-invasive modality for brain-computer interfaces (BCIs), yet reliable decoding of motor imagery is hampered by inter- and intra-individual variability.
By Xavier Vasques, Paul Barbaste, Olivier Oullier
arXiv:2607. 03094v1 Announce Type: new Abstract: Electroencephalography (EEG) decoding for brain-computer interfaces (BCIs) faces a major challenge: substantial inter-subject variability limits effective cross-subject generalization.
By Aymen Sarhane, Fouad Lbakali, Mouad Souissi, Jonathan Lys, Giulia Lioi
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
The paper introduces FRIST, a two‑stage EEG decoding framework that uses fMRI data to learn spectral projections and class geometry, then refines EEG predictions. In experiments with 12 participants, FRIST improves finger‑level motor decoding accuracy across both movement execution and motor imagery tasks, outperforming EEG‑only baselines and generalizing across different EEG backbones. The method demonstrates that fMRI’s spatial resolution can enhance noninvasive EEG‑based BCI performance.
By Jintao Zhang, Yidan Ding, Joshua Kosnoff, Maxim Karrenbach, Hanwen Wang, Bin He
arXiv:2607. 22980v1 Announce Type: new Abstract: Brain-computer interfaces (BCIs) have long sought calibration-free operation, but classifiers are typically benchmarked by discrimination alone, blind to whether predicted probabilities are well calibrated - a meaningful gap given nonstationary electroencephalogram (EEG) signals and the risk of overconfident point-estimate classifiers under distribution shift.
By Ethan Davis
arXiv:2606. 00815v1 Announce Type: new Abstract: Electroencephalography (EEG) supports a variety of brain-computer interface (BCI) tasks ranging from brain-state monitoring to human-LLM interactions.
By Ziling Lu, Zongsheng Li, Xinke Shen, Kexin Lou, Yingyue Xin, Xiaoqi Chen, Shinan Wang, Xiang Chen, Jiahao Fan, Chenyu Huang, Xin Xu, Zhoujie Hou, Chen Wei, Quanying Liu