arXiv:2602. 14913v2 Announce Type: replace Abstract: Conformal prediction (CP) offers distribution-free marginal coverage guarantees under an exchangeability assumption, but these guarantees can fail if the data distribution shifts.
By Farbod Siahkali, Ashwin Verma, Vijay Gupta
The paper introduces a partial verification approach for conformal prediction that yields the same prediction sets as full verification. It defines calibration certificates—minimal verified information needed to set the conformal threshold—and presents a coordinated verification procedure. The method reduces verification cost by 15–82% compared to sequential verification while maintaining identical prediction sets.
By Zijun Yu, Yu Gu, Vahid Partovi Nia, Masoud Asgharian
arXiv:2609.37298v1 Announce Type: new
Abstract: Conformal prediction provides set-valued predictions with distribution-free coverage guarantees, making it attractive for high-stakes image classificat...
By Julio Silva-Rodr\'iguez, Ender Konukoglu
arXiv:2606. 28598v1 Announce Type: cross Abstract: Prediction sets should have high coverage to be useful, but some coverage notions are more practically relevant than others.
By Aabesh Bhattacharyya, Tiffany Ding, Rina Foygel Barber
arXiv:2501.18060v2 Announce Type: replace-cross
Abstract: Conformal inference provides a rigorous statistical framework for uncertainty quantification in machine learning, enabling well-calibrated pr...
By Teresa Bortolotti, Y. X. Rachel Wang, Xin Tong, Alessandra Menafoglio, Simone Vantini, Matteo Sesia
The paper introduces SMART, a lightweight recalibration technique that adjusts logits based on the margin between the top two logits, called the logit gap. It uses a soft-binned Expected Calibration Error objective to balance bias and variance, enabling stable updates even with limited calibration data. Experiments across various datasets and architectures show SMART achieves state‑of‑the‑art calibration with fewer parameters than existing methods.
By Haolan Guo, Linwei Tao, Haoyang Luo, Minjing Dong, Chang Xu
arXiv:2602. 01733v3 Announce Type: replace-cross Abstract: Conformal Prediction (CP) provides a statistical framework for uncertainty quantification that constructs prediction sets with coverage guarantees.
By Junxian Liu, Hao Zeng, Hongxin Wei
arXiv:2606. 31577v1 Announce Type: cross Abstract: Conformal predictions have attracted significant attention in the field of uncertainty quantification, mainly because of their strong marginal coverage guarantees.
By Cl\'ement Fuchs, Tim Bary, Beno\^it Macq
Conformal Calibration Transfer addresses the challenge of applying conformal prediction when labeled calibration data is only available in a source space, while predictions are needed in a target space linked via unlabeled paired observations. The proposed Transported Conformal Calibration (TCC) method transports source calibration into the target domain and then corrects residual mismatches using only unlabeled target inputs, with two variants: TCC‑KS, which conservatively adjusts calibration based on a label‑free uncertainty surrogate, and weighted‑TCC, which reweights transported calibration for efficiency when weights are stable. Finite‑sample target‑domain coverage guarantees are provided, and experiments on CIFAR‑100‑C, Tiny‑ImageNet‑C, and SEN12MS demonstrate reliable coverage transfer without labeled target data, along with label‑free diagnostics to signal when correction is required.
By Achref Doula
arXiv:2608. 10372v1 Announce Type: new Abstract: Post-hoc calibration aligns a classifier's predicted confidences with its empirical accuracy without retraining.
By Lening Zhao, Qipeng Zhan, Li Shen
arXiv:2606. 03600v1 Announce Type: cross Abstract: Standard conformal prediction (CP) procedures are typically formulated in terms of p-values, but reliance on p-values alone limits flexibility, for example, when combining dependent evidence across models or data splits.
By Nabil Alami, Jad Zakharia, Souhaib Ben Taieb
The paper introduces a post‑hoc calibration method for binary segmentation models that comes with formal finite‑sample guarantees. By leveraging concentration inequalities that account for spatial dependence in segmentation outputs, the authors derive an improved theoretical bound on calibration error. Experiments show that the proposed calibrator satisfies this bound and outperforms existing post‑hoc calibration techniques.
By Bruno Viti, Martin Holler