The review examines how Uncertainty Quantification (UQ) can enhance machine learning applied to biosignals such as EEG, ECG, EOG, and EMG. It surveys 53 papers, outlining current methods, shortcomings, and theoretical frameworks, while highlighting misconceptions and gaps in diagnostic and prosthetic control contexts. The authors recommend further research on human-system interaction with UQ models in clinical settings.
By Ivo Pascal de Jong, Andreea Ioana Sburlea, Matias Valdenegro-Toro
arXiv:2608. 00943v1 Announce Type: cross Abstract: Automated sleep staging assigns discrete stage labels to successive time epochs throughout an overnight recording; conventionally each window spans at least 30 seconds, reflecting the minimum temporal resolution of the clinical scoring standard.
By Shuntian Zheng, Jiawei Wang, Cong Fu, Huan Yu, Chen Chen, Yu Guan, Sai Gu
NeuroAtlas is the largest EEG benchmark to date, comprising 42 datasets and 260,000 hours of clinical EEG data across epilepsy, sleep medicine, brain age estimation, and brain‑computer interfaces. The study evaluates foundation models (FMs) for EEG against supervised baselines and generic time‑series FMs, finding that EEG‑specific FMs do not consistently outperform generic ones. It also demonstrates that standard machine‑learning metrics are inadequate for clinical relevance, advocating for task‑specific measures such as event‑level decision quality, hypnogram features, and brain‑age gap.
By Konstantinos Kontras, Trui Osselaer, Stylianos G. Mouslech, Angeliki-Ilektra Karaiskou, Guido Gagliardi, Thomas Strypsteen, Mohammad Hossein Badiei, Anku Rani, Maarten Vanmarcke, Miguel Bhagubai, Chanakya Ekbote, Jaedong Hwang, Christos Chatzichristos, Paul Pu Liang, Maarten De Vos
arXiv:2609.22262v1 Announce Type: cross
Abstract: Medical time series (MedTS), including electrocardiograms (ECG), electroencephalograms (EEG), photoplethysmography (PPG), and vital-sign recordings,...
By Yu Han, Cigdem Beyan, Xiang Zhang, Xiaofeng Liu, Nan Liu, Jimeng Sun, Shenda Hong, Cheng Ding, Vittorio Murino
arXiv:2609.26820v1 Announce Type: cross
Abstract: Physiological time series such as electrocardiograms (ECG) and electroencephalograms (EEG) exhibit complex temporal structure, substantial acquisitio...
By Naser Mansour, Sidahmed Benabderrahmane, Ameer Rahwan
arXiv:2608. 07796v1 Announce Type: new Abstract: Large language models perform strongly on medical knowledge benchmarks, but reliable clinical deployment requires agents to conduct defensible investigations over heterogeneous, longitudinal records: determining what evidence is needed, retrieving and reconciling structured and free-text data, grounding conclusions in verifiable evidence, and deferring cases that cannot be resolved reliably.
By Veronica Chatrath, Bryan Zhu, George Pu, Jingxuan Fan, Apaar Shanker, Varun Ursekar, Anahita Sharma, Jason Qin, Keqi Han, Soham Dinesh Tiwari, Soham Dan, Vijay Kalmath, Yuan Li, Daniel Yue Zhang, Chenguang Wang, Zainab Doctor, Zhijun Yin, Nigam H. Shah, Yuan Xue
arXiv:2512. 14461v2 Announce Type: replace Abstract: Sleep is essential for health, yet studying its dynamics requires manual sleep staging, a labor-intensive step in research and clinical care.
By Niklas Grieger, Jannik Raskob, Siamak Mehrkanoon, Stephan Bialonski
arXiv:2607. 25045v1 Announce Type: new Abstract: Electroencephalography (EEG) analysis in cognitive studies requires specialized expertise and involves many defensible choices over contrasts, channels, time windows, and statistical tests.
By Dengzhe Hou, Lingyu Jiang, Fangzhou Lin, Kazunori D Yamada
The paper addresses the problem of quantization artifacts in spectral data from the Medtronic Percept PC deep brain stimulation device, which stores local field potential amplitudes as 16‑bit integers. By treating dequantization as an interval‑censored subspace estimation problem, the authors evaluate five correction methods and find that quantized probabilistic PCA most effectively reduces spurious spectral peaks while preserving true peaks and maintaining a low noise floor. The study demonstrates that over 20% of detected peaks in clinical spectra are artifacts, highlighting the need for accurate dequantization in biomarker pipelines.
By Shreesh Karjagi, Elif Ceren Fitoz, Maryam Khalid, Tanya Nauvel, Parisa Sarikhani, Helen S. Mayberg, Christopher J. Rozell, Sankaraleengam Alagapan
arXiv:2606. 09030v1 Announce Type: cross Abstract: Clinical early warning systems built on electronic health records, in which clinical observations are recorded as irregularly sampled medical time series (ISMTS), must deliver both calibrated risk scores for patient triage and interpretable rationales that clinicians can verify.
By Hyeongwon Jang, Gyouk Chu, Changhun Kim, Joonhyung Park, Hangyul Yoon, Eunho Yang
INTERVenE introduces Transformer models that use a knowledge‑based temporal abstraction (KBTA) token stream of named clinical concepts instead of raw measurements, enabling per‑token attributions to resolve directly to clinical concepts. Two variants are offered: an auto‑regressive decoder that generates future abstraction trajectories with step‑wise risk readouts, and a bidirectional encoder that jointly predicts risk and time‑to‑event in a single pass. On 57,078 MIMIC‑IV admissions, the encoder variant outperforms neural baselines with a support‑weighted AUPRC of 0.672 and AUROC of 0.901, while the decoder provides complementary token‑level risk trajectories.
By Shahar Oded, Yuval Shahar
arXiv:2608. 00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts.
By Farhan Adam Mukadam, Harshit Mishra, Nachiket Makwana, Pradyot Tiwari, Subramani Kandasamy, KVS Hari