arXiv:2608. 03690v1 Announce Type: new Abstract: Point-of-care cardiac devices such as smartwatches and handheld ECG recorders typically capture 1--2 leads, yet existing ECG foundation models are architecturally constrained to fixed 12-lead inputs, degrading or failing under these reduced configurations.
By Edoardo Coppola, Stefano Fiorini, Pietro Li\`o, Mattia Savardi, Alberto Signoroni
arXiv:2607. 23412v1 Announce Type: new Abstract: Electrocardiograms (ECGs) are widely used for cardiovascular risk prediction, yet models often fail to transfer across hospitals because of protocol, population, and measurement differences.
By Jie Lin, Weijie Sun, Sunil V. Kalmady, Anita Khalafbeigi, Abram Hindle, Padma Kaul, Russell Greiner
arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.
By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
arXiv:2608. 05893v1 Announce Type: new Abstract: Electrocardiography (ECG) is one of the most widely used non-invasive tools for diagnosing cardiovascular disease, but transforming multi-lead ECG recordings into reliable clinical reports remains challenging.
By Akanta Das, Tasinul Islam Ahon, Ahmed Mahir Sultan Rumi, Md Mahbubur Rahman, Tausif Amim Shadly, Tanzima Hashem
arXiv:2607. 07683v1 Announce Type: new Abstract: Electrocardiography (ECG) is one of the most widely used tests for diagnosing cardiovascular disease.
By Shreyasvi Natraj, Cyrus Achtari, Felice Gragnano, Andrea Milzi, Marco Valgimigli, Diego Paez-Granados
arXiv:2610.28507v1 Announce Type: cross
Abstract: Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG r...
By Walentin Palanchuk
arXiv:2606. 11556v1 Announce Type: cross Abstract: Continuous electrocardiography (ECG) monitoring could surface rhythm abnormalities before they escalate into cardiovascular events.
By Kaan Arda Akyol, Jakub Kacper Szel\k{a}g, Aydin Abadi, Maha Alghamdi, Ghadah Albalawi, Ghouse Ibrahim Kaleelullah, Hilal Tutus, Sarah Al Subaiei, Shardul Kapse, Syed Mohammed Raheeb, Mujeeb Ahmed, Rehmat Ullah
arXiv:2608. 00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts.
By Farhan Adam Mukadam, Harshit Mishra, Nachiket Makwana, Pradyot Tiwari, Subramani Kandasamy, KVS Hari
Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient p...
arXiv:2608.30367v1 Announce Type: new
Abstract: Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split h...
By Ahmed Sameh, Nolan Wilson, Max Enderlein, Yogatheesan Varatharajah
The paper introduces a self‑supervised ECG feature extraction framework trained on nearly one million unlabeled 12‑lead recordings. It comprises Deviation Localization Embedding, which identifies waveform deviations, and Association Reconstruction Embedding, which captures cross‑lead abnormal patterns. The approach yields up to 6.5% AUROC and 12.8% F1 gains on public datasets without fine‑tuning, and visualizations show meaningful disease grouping and anomaly detection.
By Siyuan Yan, Haibo Zheng, Feng Lu, Wei Li
Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-mor...