arXiv AI By Ling He, Yanxin Chen, Wenqi Wang, Shuting He, Xiaoqiang Hu

Wearable Device-Based Real-Time Monitoring of Physiological Signals: Evaluating Cognitive Load Across Different Tasks

Read the original on arXiv AI →

arXiv:2406. 07147v3 Announce Type: replace-cross Abstract: This study employs cutting-edge wearable monitoring technology to conduct high-precision, high-temporal-resolution (1-second interval) cognitive load assessment on electroencephalogram (EEG) data from the FP1 channel and heart rate variability (HRV) data of secondary vocational students.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv AI.

arXiv AI
Jun 16

A comparative and critical study of EEGNet for fNIRS-driven cognitive load classification

arXiv:2606. 16160v1 Announce Type: cross Abstract: Accurately classifying cognitive load from functional near-infrared spectroscopy (fNIRS) signals remains a significant challenge due to temporal variability, inter-subject differences, and sensitivity to preprocessing choices.

By Mehshan Ahmed Khan, Houshyar Asadi, Li Zhang, Mohammad reza Chalak Qazani, Ghazal Bargshady, Stefanos gkikas, Christian arzate, Sam Oladazimi, Zoran Najdovsk, Lei Wei, Chee Peng Lim
arXiv AI
Jul 7

CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment

arXiv:2605. 22774v3 Announce Type: replace-cross Abstract: Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects.

By Amir Mousavi, Erfan Nourbakhsh, Mohammad Sadegh Sirjani, Mimi Xie, Rocky Slavin, Leslie Neely, John Davis, John Quarles
arXiv Machine Learning
Sep 18

Towards a Unified Modality-Agnostic Multimodal Framework for Cognitive Workload Assessment

The paper presents a modality‑agnostic, hierarchical Transformer framework for assessing cognitive workload using heterogeneous biosignals. In a pilot study, the authors evaluated all 31 combinations of five modalities (ECG, EDA, RESP, SpO₂, EEG) across three tasks (IQ, MATH, GAME) and found that EEG alone performed best, while adding more modalities did not consistently improve results. The full five‑modality model achieved the highest average accuracy (73.02% on IQ, 68.08% overall) and reduced model size by about 50% compared to late‑fusion approaches.

By Stefanos Gkikas, Christian Arzate Cruz, Calvin Joseph, Giorgos Giannakakis, Raul Fernandez Rojas
arXiv AI
Aug 20

When Clean Signals Are Not Enough: Detecting Structural Ambiguity for Safe Wearable Stress Classification

The paper introduces the Individual Conformal Coupling Monitor (ICCM), a lightweight pre‑inference tool that detects structural ambiguity—when physiological signals that appear plausible individually form a pattern poorly supported by a person’s non‑stress baseline—in wearable stress classifiers. On the WESAD dataset, a Random Forest achieves high mean accuracy but fails entirely for Subject 14 due to weakened cross‑signal coupling near stress onset. ICCM quantifies subject‑specific coupling divergence and can route data to classify, defer, or abstain, reducing false positives slightly and withholding some misclassified windows, though it does not fully correct the failure.

By Saba A. Farahani, Hung Cao, Amir M. Rahmani
arXiv Machine Learning
Sep 14

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

BRIDGE-EEG is an efficient multi‑task EEG classification pipeline that leverages self‑supervised pretraining while dramatically reducing model size. It maps heterogeneous EEG recordings to a unified 62‑channel time‑frequency representation, pretrains an SE‑ResNet18 teacher with SimCLR, and distills it into smaller SE‑ResNet8 and SE‑ResNet4 students. The compact models achieve accuracy comparable to or better than larger foundation models on abnormality detection and emotion recognition, and they consume up to three times less energy on edge devices, enabling deployment on wearable hardware.

By Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen