arXiv Computer Vision By Aneesh Rangnekar, Joao Miranda, Natally Horvat, Stephanie Chahwan, Samir Alrayess, Aditya Apte, Aditi Iyer, Eve LoCastro, Revathi Ravella, Marc J Gollub, Iva Petkovska, Jesse Joshua Smith, Paul Romesser, Julio Garcia-Aguilar, Harini Veeraraghavan, Joseph O Deasy

Tumor-aware augmentation with task-guided attention analysis improves rectal cancer segmentation from magnetic resonance images

Read the original on arXiv Computer Vision →

The Flow has not summarised this story yet — read it at arXiv Computer Vision.

arXiv Computer Vision
4d ago

Learning Features, Not Layouts: Feature-Axis Attention as a Transfer Prior for Medical Imaging

The paper introduces FAD‑ViT, a vision transformer that decouples spatial and feature axes of global attention, making feature‑axis attention the primary operator. Experiments on 23 medical imaging tasks show that shifting global attention from spatial to feature leaves from‑scratch performance unchanged but significantly boosts transfer learning, achieving up to three times the gain with fewer parameters and lower compute. The study demonstrates that prioritizing feature‑axis attention is a simple, cost‑effective design choice for improving medical image transfer.

By Aon Safdar, Mohamed Saadeldin
arXiv Computer Vision
Sep 22

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

VGG16-MCA UNet is a hybrid neural network that combines an ImageNet‑pretrained VGG16 encoder with a decoder enhanced by a Multi‑Channel Attention module, trained using Focal Tversky loss to address class imbalance. The model was evaluated as a 2‑D, FLAIR‑only whole‑tumor segmenter on BraTS 2020 and LGG datasets, achieving a pixel‑level Dice of 95.10 % on BraTS and 88.32 % on LGG in a 5‑fold cross‑validation setting. Inference time is 66.32 ms per 256×256 slice on a single RTX 2060, only slightly slower than a VGG16‑UNet without attention. whyItMatters":"The study provides a reproducible 2‑D FLAIR baseline for whole‑tumor segmentation, demonstrating high Dice scores and detailed reporting of training and evaluation protocols."

By Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
arXiv Computer Vision
Aug 28

Parameter-Efficient pretrained-CT-to-MRI Transfer for Rectal Cancer Segmentation: Performance-Calibration Trade-offs

The paper introduces SWIFT, a Swin V2‑based model pretrained on 10,444 3D CT volumes and fine‑tuned for rectal cancer segmentation on T2‑weighted MRI. Four configurations—full fine‑tuning (SWIFT), decoder compression (SWIFTe), low‑rank adaptation (SWIFTe‑LoRA), and a LoRA‑decoder ensemble (SWIFTe‑LDE4)—were evaluated on 247 cases, showing that SWIFTe reduces parameters by 70.1% while improving tumor detection and radiomic agreement. The study also demonstrates a trade‑off between detection and boundary agreement, and highlights that SWIFTe‑LDE4 achieves the lowest calibration errors after temperature scaling.

By Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan