arXiv AI By Tsai-Min Chen (Research Center for Information Technology Innovation, Academia Sinica, Taipei, Taiwan, RIKEN Center for Interdisciplinary Theoretical and Mathematical Sciences), Jun Seita (RIKEN Center for Interdisciplinary Theoretical and Mathematical Sciences)

TIBECG: Temporal Information Bottleneck for Lead-Specific Demographic Privacy in ECG Waveform Release

Read the original on arXiv AI →

The paper introduces TIBECG, a temporal information bottleneck designed to protect demographic privacy in ECG waveforms while preserving diagnostic quality. Using a 2.3‑million‑parameter model, the authors evaluated the method on 6,386 twelve‑lead ECG recordings, demonstrating that TIBECG retains at least 95% of each lead’s macro‑F1 score and outperforms conventional transformations in reducing age and sex inference by a median of 22.08 percentage points. The study also highlights that direct downsampling suppresses demographic leakage more strongly but at a greater diagnostic cost, and that lead‑specific evaluation is essential for effective privacy‑preserving waveform processing.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv AI.

arXiv Machine Learning
Aug 5

LAEF: A Lead-Agnostic ECG Foundation Model Towards Point-of-Care Diagnostics

arXiv:2608. 03690v1 Announce Type: new Abstract: Point-of-care cardiac devices such as smartwatches and handheld ECG recorders typically capture 1--2 leads, yet existing ECG foundation models are architecturally constrained to fixed 12-lead inputs, degrading or failing under these reduced configurations.

By Edoardo Coppola, Stefano Fiorini, Pietro Li\`o, Mattia Savardi, Alberto Signoroni
arXiv AI
Jul 7

ImputeECG: Deep Learning Reconstruction of Complete 12-Lead Electrocardiograms from Incomplete Recordings for Cardiac Assessment

arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.

By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
arXiv AI
Aug 7

ECG-LENS: Lead-Aware Clinical Context Enriched ECG Report Generation and Evaluation

arXiv:2608. 05893v1 Announce Type: new Abstract: Electrocardiography (ECG) is one of the most widely used non-invasive tools for diagnosing cardiovascular disease, but transforming multi-lead ECG recordings into reliable clinical reports remains challenging.

By Akanta Das, Tasinul Islam Ahon, Ahmed Mahir Sultan Rumi, Md Mahbubur Rahman, Tausif Amim Shadly, Tanzima Hashem