arXiv:2607. 20814v1 Announce Type: new Abstract: The electrocardiogram (ECG) is a cornerstone of cardiac as- sessment, yet clinical deployment of deep learning models remains con- strained by limited interpretability and the hallucination risk of large language models (LLMs).
By Hai-Nam Duy Vuong, Duy-Anh Bui, Trong-Nghia Nguyen, Kim-Ngan Thi Nguyen, Trang Mai Xuan, Tien-Cuong Nguyen, Van-Dem Pham, Thien Van Luong
The paper presents a hybrid CNN–state‑space–attention backbone designed for 12‑lead ECG classification, combining early waveform tokenization, mixed temporal dynamics modeling, and late global attention. It introduces an ECG‑oriented Joint‑Embedding Predictive Pretraining (JEPA) that samples span masks at latent resolution and predicts clean latent targets via a momentum encoder, avoiding waveform reconstruction. Experiments on CPSC2018, Chapman‑Shaoxing, and PTB‑XL, with pretraining on ~350K unlabeled CODE‑15 recordings, demonstrate strong supervised baselines and improved transfer, especially in low‑label scenarios and with LoRA adaptation.
By Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
arXiv:2606. 06718v1 Announce Type: cross Abstract: Myocardial substrate abnormalities, such as myocardial scar and myocardial infarction (MI), are associated with adverse cardiovascular outcomes.
By Canyu Lei, Fenglin Zhang, Derek Bivona, Cristiane Singulane, Jonathan Pan, Kenneth Bilchick, Amit R. Patel, Jianxin Xie
BEAT-Net is a supervised biomimetic framework for ECG diagnosis that incorporates QRS-centered tokenization and a hierarchical architecture mirroring a cardiologist’s workflow. It processes heartbeat sequences through morphological, spatial, temporal, and transformer-based stages, achieving an AUC of 0.924 on large benchmarks while using only 0.7 million parameters. The model outperforms the 39.5‑million‑parameter HeartLang foundation model on morphological form classification and demonstrates superior cross‑dataset generalization with only 35% of the training data.
By Runze Ma, Haonan Lyu, Shunbo Jia, Qiang Yang, Muzi Xu, Jiaqi Zhang, Zihe Luo, Caizhi Liao
arXiv:2609.22631v1 Announce Type: new
Abstract: Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction...
By Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
ECGQuest is a new benchmark that evaluates language models on the contextual knowledge required for electrocardiogram interpretation, featuring 10,904 True/False questions derived from 23 ECG references and 2003‑2025 Computing in Cardiology proceedings. The study tested 23 commercial and open‑source models, finding that zero‑shot accuracy ranged from 49.5% to 74.4% and that fine‑tuning with Low‑Rank Adaptation improved all open‑source models by 6.5–14.1%, with the best fine‑tuned model achieving 76.3% accuracy and a five‑model ensemble reaching 78.5%. ECGQuest demonstrates that parameter‑efficient fine‑tuning can enable smaller models to compete with larger commercial ones on ECG‑specific tasks.
By Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni