Hugging Face Trending Papers

LETT-NeXt: A Lightweight RECIST-Guided Model for 3D CT Lesion Segmentation

Read the original on Hugging Face Trending Papers →

RECIST diameter measurements are widely used for tumor response assessment, but they provide only a limited 2D description of lesion extent. We present LETT-NeXt, a lightweight RECIST-guided model that predicts 3D lesion masks from CT volumes and RECIST markers for the CVPR 2026 Foundation Models for Pan-cancer Segmentation in CT Images competition.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at Hugging Face Trending Papers.

arXiv Computer Vision
Sep 22

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

VGG16-MCA UNet is a hybrid neural network that combines an ImageNet‑pretrained VGG16 encoder with a decoder enhanced by a Multi‑Channel Attention module, trained using Focal Tversky loss to address class imbalance. The model was evaluated as a 2‑D, FLAIR‑only whole‑tumor segmenter on BraTS 2020 and LGG datasets, achieving a pixel‑level Dice of 95.10 % on BraTS and 88.32 % on LGG in a 5‑fold cross‑validation setting. Inference time is 66.32 ms per 256×256 slice on a single RTX 2060, only slightly slower than a VGG16‑UNet without attention. whyItMatters":"The study provides a reproducible 2‑D FLAIR baseline for whole‑tumor segmentation, demonstrating high Dice scores and detailed reporting of training and evaluation protocols."

By Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
arXiv AI
Aug 11

Resolution Meets Reduction: Efficient Visual Context for 3D Radiology Report Generation

arXiv:2608. 08713v1 Announce Type: cross Abstract: Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges.

By Jonathan Suprijadi, Raphael Stock, Moritz Langenberg, David Zimmerer, Kim-Celine Kahl, Stefan Denner, Yannick Kirchhoff, Karol Gotkowski, Maximilian Rokuss, Jeremias Traub, Tassilo Wald, Constantin Ulrich, Klaus Maier-Hein
arXiv Computer Vision
Sep 11

Spectral Adapters for Segment Anything Model-based Segmentation of Colorectal Liver Metastases in Computed Tomography

The paper introduces two lightweight spectral adapters—Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA)—to adapt the Segment Anything Model (SAM) for accurate segmentation of colorectal liver metastases in contrast‑enhanced CT scans. SiGA achieves the highest single‑point Dice score of 0.77 and performs comparably to a 3D nnU‑Net baseline under no‑prompt inference, while DiSECT requires only 0.14 million trainable parameters. The study evaluates the adapters on 446 CT volumes across various prompting regimes, demonstrating that spectral adapters can efficiently adapt SAM with limited trainable parameters while maintaining strong segmentation accuracy.

By Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen, Yun Shin Chun, HyunSeon Christine Kang, Richard K. G. Do, Amber L. Simpson
arXiv Computer Vision
Aug 28

DALE-CT: Depth-Aware 2D Slice Encoders Learn an Anatomical World Model of Chest CT

DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.

By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner