Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
arXiv:2608.30467v1 Announce Type: new
Abstract: Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely...
By Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates...
arXiv:2608. 08046v1 Announce Type: new Abstract: Text-conditioned chest X-ray generation aims to synthesize realistic radiographs that faithfully depict specified findings.
By Pengxiang Cai, Xiaohan Li, Anglin Liu, Qingyuan Zeng, Zexun Li, Jintai Chen
arXiv:2609.27222v1 Announce Type: cross
Abstract: Pneumonia is difficult to diagnose in older long-term care residents; multimorbidity and atypical presentations obscure signs, motivating operational...
By Nicholas Rasmussen, Oleg Zaslavsky, Zih-Ling Wang, Hongyu Yu, Joelle Fathi, Kaibao Nie, Amil Khanzada, Tomoko Ito
The study evaluates a deep‑learning model for pediatric pneumonia detection across three countries, testing not only discrimination but also probability calibration, fixed operating‑point transport, shortcut signals, and limited‑label recoverability. Using a DenseNet121 ensemble trained on Guangzhou data, the model achieved high internal AUROC (0.976) but performance dropped to 0.798 and 0.742 on Bangladeshi and Vietnamese datasets, respectively. Limited‑label adaptation with Platt recalibration restored sensitivity but introduced significant specificity variability, highlighting the need for comprehensive cross‑dataset evaluation.