arXiv AI By Jingtao Lei, Hongji Li, Dexiang Shu

Layer-Wise Gate-Controlled Prompt Truncation in a Multimodal Chest X-Ray Classifier

Read the original on arXiv AI →

The paper presents a layer‑wise gating mechanism for prompt truncation in a multimodal chest X‑ray classifier based on Mixture of Prompt Experts (MoPE). The controller predicts a retention ratio per sample, averages these ratios per mini‑batch, and truncates the static and mixed visual prompts to an integer length, also scaling retained prompts by the individual ratios. In a pilot study, the gated model achieved a best validation accuracy of 0.8996 versus 0.8969 for the fixed‑length baseline, with final values of 0.8963 and 0.8802, while the gate statistics showed a retained length of one token out of a configured maximum of six, reducing the visual sequence from 210 to 200 tokens. "whyItMatters":"The study demonstrates that prompt shortening via a gating strategy can slightly improve validation accuracy in a multimodal chest X‑ray classification task, though it does not yet confirm runtime acceleration or clinical utility."

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv AI.

arXiv AI
Sep 25

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.

By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
Hugging Face Trending Papers
Sep 4

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

The study evaluates a deep‑learning model for pediatric pneumonia detection across three countries, testing not only discrimination but also probability calibration, fixed operating‑point transport, shortcut signals, and limited‑label recoverability. Using a DenseNet121 ensemble trained on Guangzhou data, the model achieved high internal AUROC (0.976) but performance dropped to 0.798 and 0.742 on Bangladeshi and Vietnamese datasets, respectively. Limited‑label adaptation with Platt recalibration restored sensitivity but introduced significant specificity variability, highlighting the need for comprehensive cross‑dataset evaluation.