arXiv:2610.34599v1 Announce Type: new
Abstract: Despite advances in automated liver lesion segmentation, a gap remains between image-derived predictions and clinically interpretable radiology reports...
By Fatma Ahmed Mansour, Rahatara Ferdousi, Manar Fathy Elshenawy
The paper introduces Diagnostic Loss (DLoss), an objective designed to align radiology report generation with the asymmetric requirement of accurately stating supported diagnoses while avoiding unsupported ones. DLoss operates on decoder token probabilities, aggregating mass over vocabularies for supported and unsupported diagnoses and applying asymmetric pooling to encourage correct diagnoses and suppress spurious ones. Applied to various 3D MedVLMs on 50,000 abdominal CT scans, DLoss improves diagnostic faithfulness without compromising conventional language‑generation metrics.
By Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jaros{\l}aw B. \'Cwik{\l}a, Arkadiusz Sitek, Pedro R. A. S. Bassi, Szymon P{\l}otka
arXiv:2604. 15231v2 Announce Type: replace Abstract: Vision-language models (VLM) have markedly advanced AI-driven interpretation and reporting of complex medical imaging, such as computed tomography (CT).
By M\'elanie Roschewitz, Kenneth Styppa, Yitian Tao, Jiwoong Sohn, Jean-Benoit Delbrouck, Benjamin Gundersen, Nicolas Deperrois, Christian Bluethgen, Julia E. Vogt, Bjoern Menze, Farhad Nooralahzadeh, Michael Krauthammer, Michael Moor
arXiv:2603.00479v2 Announce Type: replace
Abstract: Automated radiology report generation is key for reducing radiologist workload and improving diagnostic consistency, yet generating accurate report...
By Pengcheng Shi, Minghui Zhang, Kehan Song, Jiaqi Liu, Yun Gu, Xinglin Zhang
arXiv:2511. 18676v2 Announce Type: replace-cross Abstract: Current vision-language models (VLMs) in medicine are primarily designed for categorical question answering (e.
By Yongcheng Yao, Yongshuo Zong, Raman Dutt, Yongxin Yang, Sotirios A Tsaftaris, Timothy Hospedales
NV-Reason-CT is a generative vision‑language model designed for chest and abdominal CT analysis that preserves native 3D visual encoding and incorporates radiologist‑guided reasoning. The system couples a 3D vision transformer with a language model, feeding all visual tokens and their 3D coordinates directly into language decoding to maintain volumetric spatial information. Trained on a curated corpus of about 550,000 multimodal instruction examples, the model supports abnormality classification, report generation, and interactive reasoning, achieving strong performance on CT benchmarks and reducing expert interpretation time by 50%.
By Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon, Stephanie Harmon, Rikhil Makwana, Mariam Aboian, Sena Azamat, Ibrahim Ethem Hamamci, Sezgin Er, Bjoern Menze, Marc Edgar, Yufan He, Pengfei Guo, Daguang Xu