The paper introduces TriDim, a reusable block that preserves the three EEG axes—channel, short‑term temporal, and long‑term temporal—by applying feed‑forward transformations and cross‑axis attention. Stacking these blocks yields TriDimEEG, a standalone EEG decoder that outperforms fifteen other models on eight datasets, achieving a 4.3% relative accuracy gain. Replacing Transformer blocks in existing EEG foundation models with TriDim blocks improves downstream accuracy by 7.4% on average while reducing parameters by 17.0% to 47.3%.
By Shiyue Su, Song Wang, Zekai Zhan, Junjie Zeng, Ziling Lu, Zongsheng Li, Xinyuan Ye, Zhiyuan Ma, Xinke Shen, Quanying Liu
arXiv:2608.29304v1 Announce Type: new
Abstract: Translating electroencephalography (EEG) into functional magnetic resonance imaging (fMRI) is important for medical neuroimaging, clinical brain-state...
By Xiangyu Liu, Zeting Yan, Zhitong Yin, Boyang Li, Xi Zhang
arXiv:2606. 00884v1 Announce Type: cross Abstract: We study cross-subject emotion recognition from EEG, a practically important yet challenging problem in brain-computer interfaces.
By Jiaxin Qing, Lexin Li
SPERA is a new EEG foundation model that predicts in latent space using a joint-embedding predictive architecture. It incorporates a Legendre-polynomial spatial prior into attention to handle varying scalp electrode geometries, and adds factorized temporal and spatial attention with periodic full-attention blocks, plus a relational spectral regularizer to align latent similarity with spectral views. Trained on about 80,000 hours of EEG from 29,048 subjects across 106 datasets, SPERA achieves the highest average balanced accuracy on nine downstream tasks in clinical, cognitive, and BCI domains, while demonstrating strong parameter efficiency and robustness to different recording conditions.
By Minsu Kim, Ye-Sung Kim, Hyeseong Jeon, Wooseok Hyung, Joshua Lee, Chang-Hwan Im
EEG-HealthLLM introduces a hierarchical adaptation framework that unifies heterogeneous EEG health assessments using large language models. Task‑specific EEG adapters preserve unique spatio‑temporal dynamics, while a shared LoRA module in the LLM backbone captures common high‑level assessment semantics. The new EEG‑HealthBench benchmark reorganizes five EEG datasets into five health‑assessment tasks, and experiments show EEG‑HealthLLM achieves the highest average balanced accuracy and macro‑F1, improving performance while reducing adapter size by 80%.
By Ruidong Ma, Jisheng Dang, Ronghao Lin, Bimei Wang, Jingwen Zhao, Wenjun Ma, Wei-Shi Zheng, Meng Wang, Qi Tian, Tat-Seng Chua
arXiv:2610.27521v1 Announce Type: new
Abstract: Multimodal physiological signals provide complementary cues for emotion recognition. They also raise two related challenges. Emotion-related EEG patter...
By Jian Zhang, Manrong Liu, Yilei Huang, Wenhua Liu, Xiaohui Yang, Lijun Yang