arXiv:2608. 14763v1 Announce Type: cross Abstract: Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement.
By Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant, Davood Karimi
arXiv:2607. 18283v1 Announce Type: cross Abstract: Accurate localization of the corpus callosum (CC) in fetal ultrasound (US) images is crucial for the early identification of neurodevelopmental abnormalities.
By Alessandro Di Matteo, Sara Moccia, Giuseppe Rizzo, Gianpaolo Grisolia, Ricciarda Raffaelli, Lorenzo Vasciaveo, Francesco D'Antonio, Maria Chiara Fiorentino
arXiv:2607. 20136v1 Announce Type: cross Abstract: Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations.
By Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra
arXiv:2606. 01293v1 Announce Type: cross Abstract: Accurate segmentation of fetal brain tissues in Magnetic Resonance Imaging (MRI) is critical for early diagnosis of congenital abnormalities and improving prenatal care.
By Ashiqur Rahman, Muhammad E. H. Chowdhury, Md. Abu Sayed, Md. Sharjis Ibne Wadud, Abu Naser Md. Arafat, Mehedi Hasan Prince
arXiv:2606. 20172v1 Announce Type: new Abstract: Preterm birth is associated with significant mortality and a risk for lifelong morbidity.
By Diego Fajardo-Rojas, Megan Hall, Daniel Cromb, Mary A. Rutherford, Lisa Story, Emma C. Robinson, Jana Hutter
FETALFusion is a dual‑path CNN‑Mamba encoder‑decoder designed for fetal head segmentation in 2D ultrasound across transabdominal and transperineal acquisition types. It uses four‑directional state‑space scans at the highest‑resolution stages, domain‑specific channel gates, and a weak landmark shape prior, achieving a Dice score of 0.963 and an HD95 of 2.10 mm on a held‑out test set of 471 images. Ablation studies show that the landmark prior and domain gates drive most of the performance gains, while the state‑space branch has minimal impact.
whyItMatters":"The method provides highly accurate fetal head segmentation without test‑time augmentation or domain labels, enabling reliable head circumference measurement for monitoring fetal growth."
By Ammar Bhilwarawala, Mainak Bandyopadhyay