Evaluating the Impact of Nonlinear Registration on Longitudinal PET Analysis in a Rodent Stroke Model
Read the original on Hugging Face Trending Papers →The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
arXiv:2608. 08173v1 Announce Type: cross Abstract: Longitudinal MRI enables sensitive measurement of structural brain change for studying aging and neurodegenerative disease.
The paper presents a diffeomorphic coarse‑to‑fine LapIRN architecture adapted for longitudinal whole‑body PSMA PET/CT registration in the Learn2Reg 2026 PSMAReg challenge. The method integrates affine pre‑registration, multi‑modal deformable registration, and test‑time instance optimization, and introduces PET biomarker preservation losses for metabolic tumor volume (MTV) and total lesion glycolysis (TLG) with Jacobian‑based constraints and per‑structure rigidity regularization for skeletal structures. The submitted configuration achieved 81.0 % Dice similarity coefficient, 6.17 mm HD95, and 3.3 % errors in MTV and TLG on the evaluation protocol.
The paper introduces DB‑SUiT, a surface‑based diffusion bridge that translates cortical MRI to PET images directly on the cortical manifold. It employs a conditional spherical U‑shaped vision Transformer to capture multi‑scale surface features and long‑range dependencies while incorporating demographic and subcortical information. Evaluations on two dementia datasets show that the synthesized PET surfaces outperform MRI and PET volumes in automated classification and achieve high diagnostic accuracy in a blinded reader study.
arXiv:2608. 19769v1 Announce Type: cross Abstract: Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning.
arXiv:2508.17171v3 Announce Type: replace Abstract: Imaging biomarkers in magnetic resonance imaging (MRI) are important tools for diagnosing, tracking and treating Alzheimer's disease (AD). Neurofib...
The paper presents a method for the BIC-MAC challenge, aiming to generate pseudo‑CT images from NAC‑PET, DIXON MRI, and a topogram, and to evaluate both the pseudo‑CT and the resulting attenuation‑corrected PET. The authors improve upon a 3D U‑Net baseline by focusing on loss design: they compute an L1 error in the Carney attenuation‑coefficient space, weighted by anatomical region, and incorporate DIXON MRI as additional input only after this loss was applied. Finally, they fuse two independently trained models via a fixed convex combination, achieving better performance than either model alone and topping the public validation leaderboard.