Clinical radar heart sounds with echocardiographic phenotypes of ventricular dysfunction and valvular disease
Read the original on Hugging Face Trending Papers →The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
The paper presents a new dataset of 537 radar heart‑sound recordings, each paired with an echocardiographic report from 162 patients. The cohort includes three overlapping cardiac phenotypes—reduced left ventricular ejection fraction, regional wall‑motion abnormality, and moderate or greater valvular regurgitation—allowing signal‑to‑phenotype analysis. Technical validation shows high signal retention and reproducible waveform reconstruction, and a five‑fold evaluation yields an AUROC of 0.770±0.138 for detecting reduced ejection fraction.
arXiv:2608. 14723v1 Announce Type: cross Abstract: Reduced left ventricular ejection fraction (LVEF) is frequently asymptomatic and often detected only after advanced heart failure develops.
EchoAlign is a vision‑language foundation model for echocardiography that aligns each cardiac structure, video, and study with its corresponding report text, using a visibility matrix to restrict supervision to the views that actually depict each structure. Trained on 2.87 million videos and images from 159 clinical centers, it outperforms five public foundation models on 0.47 million test videos from ten unseen external datasets, achieving a mean AUROC of 0.890 for classification and a mean quadratic weighted kappa of 0.530 for severity grading. The model can detect findings, grade severity, estimate measurements, and segment cardiac structures across 62 clinical findings.
Echocardiography assesses the structure and function of the heart. Cardiologists read each study across several standard views and report the findings visible in those views by cardiac structure. AI f...
EchoXFlow is a new clinical echocardiography dataset that preserves ultrasound recordings in their native acquisition geometry, offering 35,377 recordings from 666 routine-care examinations of 622 patients. Unlike existing datasets, it retains separate modality streams—including temporally resolved 1D, 2D, and 3D data, multiple Doppler modalities, and synchronized ECG—along with clinical annotations ranging from guideline-defined measurements to dense 2D myocardial contours and 3D left‑ventricular endocardial meshes. The accompanying open‑source tooling enables cross‑modal, acquisition‑aware learning tasks that are impossible with conventional scan‑converted videos, positioning EchoXFlow as a testbed for 4D vision and physically grounded multi‑modal learning.
arXiv:2607. 16220v1 Announce Type: cross Abstract: Heart disease kills a lot of people, and one cheap way to catch it early is by listening to heart sounds with a stethoscope, or better yet, just recording them and running them through a model.