arXiv:2609.12574v1 Announce Type: new
Abstract: Ultra-widefield (UWF) swept-source optical coherence tomography angiography (SS-OCTA) enables large-area retinal vascular imaging, yet vessel segmentat...
By Yang Liu, Yibing Shen, Keming Zhao, Cenk Jiang, Zhenghang Qian, Zhicheng Du, Chen Xiong, Qidong Shao, Zijun Lin, Yunqi Hu, Jingjing Zhou, Lian Zhang, Peter E. Lobie, Peiwu Qin, Chengming Yang
The paper introduces D$^2$Mamba, a model that combines non‑causal state‑space duality with deformable Mamba scanning to better segment small, irregular diabetic retinopathy lesions. Using five‑fold cross‑validation on the DDR dataset, D$^2$Mamba outperforms baseline methods, achieving 33.87% mIoU and a 10.06‑point Dice improvement on microaneurysms. The authors provide code and pretrained weights on GitHub.
By Chang Yu, Siqing Li, Yuanchen Liu, Zhenyu Bu, Luming Yang, Alper Yilmaz
arXiv:2610.35357v1 Announce Type: new
Abstract: Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structura...
By Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo, Yuhui Deng, Huaxiong Huang
arXiv:2609.26189v1 Announce Type: new
Abstract: Retinal vessel segmentation in multi-domain deployment requires a source model to adapt to domains that differ in imaging conditions and annotation con...
By Yongsong Huang, Tomo Miyazaki, Kai Xu, Xiaofeng Liu, Yaohou Fan, Shinichiro Omachi
OptiModNet is a lightweight UNet‑Transformer hybrid designed for optic disc and cup segmentation. It incorporates grouped‑query and channel attention across multiple stages, along with an Aggregated Pyramid Loss to improve gradient flow and structural consistency. Evaluated on the REFUGE2 dataset, it surpasses existing methods by over 2.5 % while using only 3.73 GFLOPs and 1.93 M parameters.
By Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
The paper presents a two‑pipeline framework for retinal fundus analysis that combines four‑class disease classification with vessel segmentation. It fine‑tunes eight ImageNet‑pretrained CNNs on the FIVES dataset, applies five gradient‑based explanation methods to assess model interpretability, and benchmarks ten U‑Net variants—including transformer‑based and attention‑enhanced architectures—on the FIVES and DRIVE datasets. The best classification results come from ResNet101 (94.17% accuracy), while the strongest segmentation performance is achieved by Attention U‑Net with a ResNet101V2 backbone, improving DRIVE IoU from 60.80% to 64.83%.
By Fatema Tuj Johora Faria, Mukaffi Bin Moin, Pronay Debnath, Asif Iftekher Fahim, Faisal Muhammad Shah
arXiv:2608.17623v2 Announce Type: replace
Abstract: Retinal diseases are a leading cause of irreversible vision impairment, making early and accurate diagnosis essential for effective treatment. Opti...
By Cheng Cheng, Jin Hong
Accurate coronary Digital Subtraction Angiography (DSA) vessel segmentation is essential for computer-aided diagnosis and treatment planning of coronary artery disease (CAD). However, thin low-contrast vessels, background interference, and severe vessel-background class imbalance make reliable segmentation of weak distal branches and vessel boundaries challenging.
arXiv:2608. 12274v1 Announce Type: cross Abstract: Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy.
By Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim, Justine Cunningham, Hassan Bagher-Ebadian, Dongxiao Zhu, Kundan S. Thind
arXiv:2606. 05375v1 Announce Type: cross Abstract: Optical coherence tomographic angiography (OCTA) is a powerful technique for imaging retinal microvasculature.
By Yukun Guo, Min Gao, Tristan T. Hormel, Steven T. Bailey, Thomas S. Hwang, Yali Jia
The paper introduces a geometry‑guided sampling operator that directs feature sampling rather than altering convolution kernels in 3D encoder‑decoder networks. By predicting local orientations and bounded step sizes, the operator samples symmetrically around each voxel, generating compact geometric and boundary cues that improve fine‑structure segmentation. Replacing stride‑1 and stride‑2 operations in a 3D U‑Net yields consistent gains on BraTS, MSD Hepatic Vessel, and TDSC‑ABUS datasets, with better boundary metrics and fewer parameters, and the operator can be integrated into other backbones without architectural changes.
By Sizhe Wang, Himashi Peiris, Zhaolin Chen
arXiv:2606. 19824v1 Announce Type: cross Abstract: Accurate segmentation of thin, tortuous anatomical structures, such as retinal vessels, cerebral vasculature, and facial wrinkles, remains challenging due to low contrast, frequent discontinuities, and severe class imbalance.
By Junho Moon, Haejun Chung, Ikbeom Jang