The paper evaluates deep learning models for electrocardiogram‑based emotion recognition, focusing on generalization across datasets rather than dataset‑specific performance. It introduces two open‑source tools—ARRC for standardized benchmarking and ARDT for inter‑dataset training—to merge three public AER datasets (CUADS, ASCERTAIN, DREAMER) into a more variable benchmark. Using these tools, the authors compare three prominent deep learning architectures and two CNN baselines with hyperparameter tuning and 10‑fold cross‑validation, revealing trade‑offs between accuracy and model complexity and providing a reproducible benchmark for future research.
By Timothy C Sweeney-Fanelli, Ajan Ahmed, Masudul Imtiaz
arXiv:2608. 06122v1 Announce Type: cross Abstract: Inspired by recent evidence that transformer architectures benefit from Self-PreTraining (SPT) on long-context benchmarks, we investigate whether similar gains extend to multimodal, multivariate, and even simple univariate medical time series.
By Omar Coser, Antonio Orvieto, Paolo Soda, Loredana Zollo
The study compares temporal deep learning models—Bidirectional LSTM, Temporal Convolutional Network, and Transformer—for physiological emotion recognition using two multimodal wearable datasets, WESAD and EmoWear. Experiments evaluate wrist-only, chest-only, and multimodal sensor configurations with participant-independent leave-one-subject-out cross-validation, and also explore ensembles, sensor ablation, sampling frequency, and saliency analysis. Results show that the best architecture varies by dataset, multimodal sensing consistently outperforms single-site configurations, and a 4 Hz sampling rate offers a cost-effective operating point.
By Desta Haileselassie Hagos, Saurav Keshari Aryal, Legand L. Burge
arXiv:2608. 16541v1 Announce Type: cross Abstract: Objective assessment of learning remains a fundamental challenge in education.
By Isuru Nanayakkara, Thilina Halloluwa
arXiv:2607. 20814v1 Announce Type: new Abstract: The electrocardiogram (ECG) is a cornerstone of cardiac as- sessment, yet clinical deployment of deep learning models remains con- strained by limited interpretability and the hallucination risk of large language models (LLMs).
By Hai-Nam Duy Vuong, Duy-Anh Bui, Trong-Nghia Nguyen, Kim-Ngan Thi Nguyen, Trang Mai Xuan, Tien-Cuong Nguyen, Van-Dem Pham, Thien Van Luong
arXiv:2608. 14675v1 Announce Type: cross Abstract: While Self-Supervised Learning (SSL) effectively extracts general representations from noisy, unconstrained physiological signals such as photoplethysmography (PPG), its suitability for highly subjective tasks remains unproven.
By Dominika Kunc, Przemys{\l}aw Kazienko, Stanis{\l}aw Saganowski
arXiv:2607. 10784v1 Announce Type: cross Abstract: Deploying deep learning models for automated electrocardiogram classification on resource-constrained wearable devices remains challenging due to high computational costs.
By Yi Zhao, Jiajun Gao, Chenyang Xu, Yuxi Zhou, Hao Wang
arXiv:2606. 24985v1 Announce Type: new Abstract: Personalization in wearable-based stress detection remains challenging due to substantial inter-individual variability in physiological and behavioral responses.
By Louis Simon, Mohamed Chetouani
arXiv:2608. 13409v1 Announce Type: new Abstract: Existing predictive models in learning analytics often treat student academic history as a simple sequence, overlooking the concurrent nature of courses taken within a semester.
By Paul Savala
arXiv:2607. 01145v1 Announce Type: new Abstract: Data analysis in the medical domain often encounters scenarios involving a limited target dataset and a large, unannotated dataset with a general distribution.
By Siwon Kim
arXiv:2607. 01145v2 Announce Type: replace Abstract: Data analysis in the medical domain often encounters scenarios involving a limited target dataset and a large, unannotated dataset with a general distribution.
By Siwon Kim
arXiv:2507. 12645v1 Announce Type: cross Abstract: The increasing need for accurate and unified analysis of diverse biological signals, such as ECG and EEG, is paramount for comprehensive patient assessment, especially in synchronous monitoring.
By Mohammed Guhdar, Ramadhan J. Mstafa, Abdulhakeem O. Mohammed