SOTER is a generative foundation model designed for wearable physiological time‑series data. It integrates cross‑channel coupling, spectrum‑guided expert specialization, and continuous‑time latent evolution, using a spatial feature‑aware backbone, a PSD‑guided mixture‑of‑experts layer, and a neural controlled differential equation decoder. Trained on 226 billion time points from five public datasets, SOTER outperforms baselines in zero‑shot forecasting, classification, and imputation across six benchmarks, and remains robust to additive noise.
By Fangke Chen, Sirry Chen, Wei Chen, Zhongyu Wei
arXiv:2606. 24985v1 Announce Type: new Abstract: Personalization in wearable-based stress detection remains challenging due to substantial inter-individual variability in physiological and behavioral responses.
By Louis Simon, Mohamed Chetouani
Time-series foundation models have demonstrated strong cross-domain transfer, yet their common architectural assumptions remain poorly aligned with wearable physiological signals, which are multichann...
LiteEMG-FM is an efficient hybrid CNN‑Transformer foundation model designed for electromyography (EMG) sensing. It is pretrained on 16 diverse upper‑ and lower‑limb EMG datasets, enabling representations that generalize across users and datasets. The model incorporates a lightweight, always‑on 1D‑CNN wake‑up module that filters rest and non‑target activity, activating LiteEMG‑FM only for valid gestures, and is evaluated in full inference offloading, split inference, and full on‑device processing scenarios, showing superior performance over state‑of‑the‑art time‑series foundation models and supervised baselines, especially in zero‑calibration cross‑participant and data‑scarce conditions.
By Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu, Phuc Nguyen, Jian Liu
arXiv:2607. 16235v1 Announce Type: cross Abstract: Mobile and wearable devices offer an unprecedented opportunity for continuous, passive health monitoring and active health coaching.
By Narayan Schuetz, Yuze Bai, Lianggang Pan, Edgar Eggert, Favour Nerrise, Juan Delgado-SanMartin, Max Rosenblattl, Milana Gurbanova, Mohammad Asadi, Anders Johnson, Paul Schmiedmayer, Dennis Wang, Allan Lawrie, Daniel Seung Kim, Xin Liu, Akshay Paruchuri, Ehsan Adeli, Euan Ashley, Kelly W. Zhang
arXiv:2605. 22759v2 Announce Type: replace Abstract: While ubiquitous wearable sensors capture a wealth of behavioral and physiological information, effectively transforming these signals into personalized health insights is challenging.
By Girish Narayanswamy, Maxwell A. Xu, A. Ali Heydari, Samy Abdel-Ghaffar, Marius Guerard, Kara Vaillancourt, Zhihan Zhang, Jake Garrison, Levi Albuquerque, Dimitris Spathis, Hong Yu, Hamid Palangi, Xuhai "Orson" Xu, David G. T. Barrett, Joseph Breda, Jed McGiffin, Yubin Kim, Yuwei Zhang, Naghmeh Rezaei, Samuel Solomon, Karan Ahuja, Tim Althoff, Jake Sunshine, Ming-Zher Poh, Benjamin Yetton, Ari Winbush, Nicholas B. Allen, James M. Rehg, Isaac Galatzer-Levy, Yun Liu, John Hernandez, Anupam Pathak, Conor Heneghan, Yuzhe Yang, Ahmed A. Metwally, Pushmeet Kohli, Mark Malhotra, Shwetak Patel, Xin Liu, Daniel McDuff
EMG-FM-Bench is a benchmark that unifies 20 public electromyography datasets, totaling over one million EMG segments, to evaluate how foundation models transfer and adapt to EMG tasks. It tests nine pretrained models across four scenarios: frozen versus fully fine‑tuned performance, the benefit of pretraining versus training from scratch, generalization to new users with limited data, and performance across different EMG tasks. Results show that linear probing reveals useful pretrained representations, full fine‑tuning can significantly alter performance, pretraining benefits vary by model, performance drops on new users, and few‑shot adaptation improves macro‑F1 in most cases but only partially recovers lost performance.
By Tianhao Wu, Jiawei Yu, Xiangdong Hu, Xu Wu, Hongyu Wu, Sidharth Anupkrishnan, Amirmohammad Radmehr, Yi Chen Liu, Phuc Nguyen, Yi Wu, Jian Liu
arXiv:2605. 22774v3 Announce Type: replace-cross Abstract: Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects.
By Amir Mousavi, Erfan Nourbakhsh, Mohammad Sadegh Sirjani, Mimi Xie, Rocky Slavin, Leslie Neely, John Davis, John Quarles
arXiv:2411. 15240v5 Announce Type: replace-cross Abstract: Wearable movement data is collected by nearly all commercially available smartwatches and is a valuable resource for mental health research, reflecting fine-grained temporal behavioral trends.
By Franklin Y. Ruan, Aiwei Zhang, Jenny Y. Oh, SouYoung Jin, Nicholas C. Jacobson
TimeCap is an open, deterministic pipeline that generates text captions for wearable health time‑series data without using a language model in the loop. It consists of three reusable extractor tiers and a cross‑channel synthesis layer, allowing new schemas to be added by defining channel mappings. Applying TimeCap to the MyHeart Counts dataset produced MHCap, the largest open caption layer for multimodal wearable data, containing 7,005,763 captions over 908,944 person‑days across 19 Apple HealthKit channels.
By Max Rosenblattl, Milana Gurbanova, Karl Aurel Deck, Narayan Schuetz, Thomas Kaar, Manuel Milling, Nicolas Zumarraga, Ning Wang, Kelly W. Zhang, Anders Johnson, Robert Jakob, Bj\"orn W. Schuller, Elgar Fleisch, Daniel Seung Kim, Allan Lawrie, Patrick Langer, Maxwell A. Xu, Euan Ashley, Paul Schmiedmayer
BRIDGE-EEG is an efficient multi‑task EEG classification pipeline that leverages self‑supervised pretraining while dramatically reducing model size. It maps heterogeneous EEG recordings to a unified 62‑channel time‑frequency representation, pretrains an SE‑ResNet18 teacher with SimCLR, and distills it into smaller SE‑ResNet8 and SE‑ResNet4 students. The compact models achieve accuracy comparable to or better than larger foundation models on abnormality detection and emotion recognition, and they consume up to three times less energy on edge devices, enabling deployment on wearable hardware.
By Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
Brain4FMs is a unified benchmark for evaluating brain foundation models (BFMs) on both scalp EEG and intracranial EEG (iEEG). It incorporates 17 representative models and 21 public datasets spanning clinical diagnosis, sleep staging, communication, and affective computing, and offers dataset-aware preprocessing, cross‑subject evaluation, and standardized downstream workflows. The benchmark highlights that no single BFM consistently outperforms others across all tasks, modalities, and adaptation protocols, prompting further exploratory analyses of model‑specific spatial, spectral, and discrete representations.
By Fanqi Shen, Enhong Yang, Jiahe Li, Junru Hong, Xiaoran Pan, Zhizhang Yuan, Meng Li, Yang Yang