arXiv:2604.22784v2 Announce Type: replace
Abstract: Power System State Estimation (PSSE) converts geographically distributed measurements into the voltage magnitudes and phase angles needed for grid...
By Solon Falas, Markos Asprou, Charalambos Konstantinou, Maria K. Michael
arXiv:2607. 16031v1 Announce Type: cross Abstract: Data-driven pre-fault dynamic security assessment (DSA) rapidly evaluates the dynamic risk of credible contingencies on a power system using machine learning.
By Olayiwola Arowolo, Maosheng Yang, Jochen Cremer
arXiv:2605. 28912v2 Announce Type: replace Abstract: The rapid growth of AI-driven data centers and large-scale energy storage systems is increasing the reliance of power system operation on real-time measurement data and automated decision-making.
By Xin Li, Chenhan Xiao, Jonathan Cohen, Aviad Elyashar, Yang Weng, Rami Puzis
EvEMTBench is an open, executable, and versioned benchmark designed to standardize the evaluation of machine‑learning methods for power system protection. It defines 12 protection and event‑analysis functions across four grids (20–345 kV) as 24 scored tasks, enabling structured assessment under varied observability, distribution shifts, and cross‑grid transfer scenarios. The benchmark includes committed data partitions, leakage controls, and reproducible reporting, and demonstrates that wider observability does not always help, that shifted conditions expose hidden failures, and that fault detection transfers better than fault localization.
By Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
The paper introduces PCGAN, a physics-constrained generative adversarial network that learns power‑flow sensitivities from historical sensor data to craft stealthy false data injection attacks on smart grids. PCGAN limits perturbations to compromised channels while producing realistic spatiotemporal patterns, and it outperforms seven existing attacks on the IEEE 300‑bus system across various levels of sensor compromise. The study evaluates PCGAN’s stealth against ten machine‑learning detectors and conventional bad‑data detection methods, showing high evasion rates and significant physical impact, thereby offering challenging scenarios for detector evaluation.
By Md. Mainul Islam, Hasan Kurban, Abdulrahman Takiddin, Muhammad Ismail, Rachad Atat, Erchin Serpedin
arXiv:2606.
By Farhin Farhad Riya, Shahinul Hoque, Yingyuan Yang, Jinyuan Sun, Kevin Tomsovic
The paper introduces a method that uses a single deep neural network, trained only on basecase AC power flow data, to predict post-contingency operating states for any single-line outage. It frames this prediction as a fixed-point iteration and provides sufficient convergence conditions, certifying them via semidefinite programming. Numerical experiments on the IEEE 118-bus system show that the certified conditions hold for all tested contingencies and that accurate state estimates are achieved in only a few iterations.
By Md Obaidur Rahman, Junjie Qin, Vassilis Kekatos
arXiv:2603. 10676v2 Announce Type: replace Abstract: Industrial Control Systems (ICS) underpin critical infrastructure and face growing cyber-physical threats due to the convergence of operational technology and networked environments.
By Kosti Koistinen, Kirsi Hellsten, Joni Herttuainen, Kimmo K. Kaski
arXiv:2608. 16494v1 Announce Type: cross Abstract: Modern power systems face growing operational complexity driven by the integration of renewable energy sources, decentralization, and the need for real-time decision-making across a wide range of timescales.
By Martin Sadric, Sebastian P\"utz, Christian Nauck, Veit Hagenmeyer, Frank Hellmann, Dirk Witthaut, Benjamin Sch\"afer
The paper evaluates three machine‑learning fault detectors—gradient‑boosted trees, a convolutional neural network, and logistic regression—against a reference sequence‑current method on 9,022 simulated 90 kV line fault episodes. Using a protection‑oriented assessment framework that includes multiple window conditions, causal labeling, episode‑grouped cross‑validation, and a fixed security budget, the authors report near‑perfect AUC‑ROC (>0.999) but reveal that missed‑trip rates can reach 1.99 % and false‑trip rates 0.12–0.16 % per window, with nuisance assertions in 11.3–19.1 % of episodes. The study also finds that higher fault resistance correlates most consistently with missed trips and that a fault‑current gradient is only partially captured by waveform‑derived current.
whyItMatters":"The assessment demonstrates that high aggregate performance metrics can mask significant protection‑relevant errors, highlighting the need for protection‑oriented evaluation of ML fault detectors."
By Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
arXiv:2607. 14640v1 Announce Type: new Abstract: Battery health estimation is fundamental for battery management in battery-powered systems, where inaccurate health states may affect control, maintenance, and service life.
By Wen Yang Tan, Jiawei Li, Fang Liu, Wei Zhang, Sumei Sun, Peng Cheng Wang, Elisa Y. M. Ang
arXiv:2606. 25200v1 Announce Type: new Abstract: The accelerated digitalization of renewable energy smart grids through IoT sensors, AMI, and SCADA systems has significantly expanded the attack surface for sophisticated cyberattacks, FDI attacks that stealthily distort state estimation and DoS/DDoS attacks that flood communication channels.
By Sajib Debnath, Remon Das