arXiv:2505. 17338v3 Announce Type: replace-cross Abstract: Photorealistic volumetric rendering of CT scans greatly benefits clinical workflows, yet neural approaches such as Neural Radiance Fields (NeRF) and 3D Gaussian Splatting (3DGS) require prohibitive per-scan optimization (hours for NeRF, about 30 minutes for 3DGS), making them impractical in clinical settings.
By Zhongpai Gao, Benjamin Planche, Meng Zheng, Anwesa Choudhuri, Van Nguyen Nguyen, Terrence Chen, Ziyan Wu
FactorSplat introduces a per-scene N‑dimensional Gaussian splatting proxy that allows region‑specific intensity‑to‑RGBA curves to be applied at inference, enabling appearance control in medical volume rendering. The method uses a shared functional encoder and low‑rank per‑Gaussian factors to learn residual appearance while keeping geometry and directional appearance shared across presets. Experiments on seven CT and MR scans show that FactorSplat outperforms region‑aware VEG in mean PSNR and changed‑region error across validation, interpolation, unseen composition, and out‑of‑distribution edits, achieving 1.10 to 1.52 dB PSNR gains and supporting fast TF switches at 524 FPS.
By Zhongpai Gao, Benjamin Planche, Meng Zheng, Anwesa Choudhuri, Terrence Chen, Ziyan Wu
arXiv:2607. 13682v2 Announce Type: cross Abstract: Radiative Gaussian splatting reconstructs sparse-view CT fast and accurately, and recent work attaches per-Gaussian posteriors to yield per-voxel uncertainty maps.
By Chulin Zhao, Yiran Xu, Shu Liu
arXiv:2608. 14112v1 Announce Type: cross Abstract: Scientific simulations often produce scalar volumes faster than they can be stored, transferred, and loaded, while in situ reduction must use only a limited share of simulation resources.
By Michael R. Martin, Joseph Insley, Victor A. Mateevitsi, Silvio Rizzi, Kwan-Liu Ma
arXiv:2608. 08713v1 Announce Type: cross Abstract: Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges.
By Jonathan Suprijadi, Raphael Stock, Moritz Langenberg, David Zimmerer, Kim-Celine Kahl, Stefan Denner, Yannick Kirchhoff, Karol Gotkowski, Maximilian Rokuss, Jeremias Traub, Tassilo Wald, Constantin Ulrich, Klaus Maier-Hein
arXiv:2607.13682v4 Announce Type: replace-cross
Abstract: Does an uncertainty map identify where a reconstruction is wrong? In sparse-view computed tomography (CT), we find a sharp gap between whole-...
By Chulin Zhao, Yiran Xu, Shu Liu
DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.
By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner
arXiv:2608.00231v2 Announce Type: replace
Abstract: Volumetric CT vision-language pretraining learns 3D representations from scan-report pairs, but global and anatomy-aware objectives supervise only...
By Guoliang You, Haifan Gong, Xiaomeng Chu
arXiv:2609.31248v2 Announce Type: replace
Abstract: 3D Gaussian Splatting reconstructs a scene from a set of posed photographs called the capture; Gaussian count affects reconstruction quality, stora...
By Afif Boudaoud, Jiayi Liu, Alexandru Calotoiu, Torsten Hoefler
XClipGS introduces an exact half‑space clipping method for Gaussian‑splatting of medical volumes, enabling precise rendering of clipped anatomy without learned clipping parameters. The technique factorizes the ray integral into a 2D footprint and a conditional Gaussian CDF, remaining differentiable and efficient. Evaluated on eight CT and MRI datasets, XClipGS outperforms prior methods in PSNR, SSIM, and leakage while achieving over 650 FPS.
By Zhongpai Gao, Benjamin Planche, Meng Zheng, Anwesa Choudhuri, Chaoyi Zhou, Terrence Chen, Ziyan Wu
TAN (Tissue‑Aware Network) is a lightweight convolutional encoder that processes tissue‑conforming superpixels in their native shape, avoiding background leakage from padding or masking. It achieves accuracy on the BACH histology dataset comparable to a 303‑million‑parameter foundation model while using only 0.41 M parameters and 1,190× fewer FLOPs, and its embeddings are invariant to the choice of fill value. On the BRACS dataset, TAN performs close to a ResNet18 trained under the same protocol and outperforms standard masked‑crop processing with less than half the computational cost.
By Jan Herschel, Anselm von Gladiss
arXiv:2610.27712v1 Announce Type: cross
Abstract: Feed-forward 3D Gaussian Splatting (FF3DGS) reconstructs 3D scenes from images in a single forward pass, making it well-suited to applications that m...
By Injae Kim, Minseok Joo, Jihwan Park, Sehyung Kim, Minseong Bae, Hyunwoo J. Kim