The paper introduces FALLNEST, a data‑centric framework that condenses large, imbalanced inertial measurement unit (IMU) datasets into tiny, class‑balanced synthetic training sets for wearable fall detection. FALLNEST builds on dual‑domain time‑series condensation, adding a fall‑specific 7‑channel input, class‑balanced K‑Means initialization, normalized gradient matching with clipping, MMD‑based embedding alignment, and multi‑view Fourier‑domain augmentation. Experiments on SisFall, KFall, and MobiFall show that a 102K‑parameter TinyCNN trained on only 32 to 146 synthetic windows (≈1% of the original data) achieves 93.5–95.8% mean accuracy and 0.89–0.98 PR‑AUC with low variance.
By Rashi Niyas P, Ritika Jain, Hitika Tiwari
arXiv:2608. 13197v1 Announce Type: new Abstract: Falls are a major health concern for older adults, and wearable sensors have been widely explored for detecting falls and enabling timely intervention.
By Timilehin B. Aderinola, Ilaria D'Ascanio, Luca Palmerini, Lorenzo Chiari, Jochen Klenk, Clemens Becker, Brian Caulfield, Georgiana Ifrim
Falls are a major health concern for older adults, and wearable sensors have been widely explored for detecting falls and enabling timely intervention. However, real-world falls are extremely rare: collecting 100 of them requires an estimated 100,000 days of monitoring, resulting in severely limited labelled data for training machine learning models.
arXiv:2608. 05782v1 Announce Type: cross Abstract: Wearable human activity recognition (HAR) is often limited by the scarcity of labeled sensor data, especially in low-resource, class-imbalanced, and subject-generalization settings.
By Lala Shakti Swarup Ray, Vitor Fortes Rey, Mengxi Liu, Paul Lukowicz, Bo Zhou
arXiv:2606. 10250v1 Announce Type: cross Abstract: Class imbalance is a common problem in deep learning that severely degrades performance.
By Haengbok Chung, Jae Sung Lee
arXiv:2610.27443v1 Announce Type: new
Abstract: Set-valued classification (SVC) offers a practical approach to communicating uncertainty while maintaining accuracy by predicting variable-sized sets p...
By Kevin Kasa, Scott C. Lowe, Graham W. Taylor
HALO is a heterogeneity‑aware, language‑aligned foundation model for inertial measurement unit (IMU) based human activity recognition. It uses a two‑stage training process: first, a self‑supervised encoder learns to handle diverse sensor configurations and natural‑language sensor descriptions; second, the encoder is aligned with text embeddings through synonym‑aware contrastive learning, enabling open‑set recognition via cosine similarity. Trained on ten public HAR datasets, HALO outperforms five state‑of‑the‑art baselines across eight metrics while using only ~35 M parameters, and improves zero‑shot open‑set accuracy by 13.7 percentage points over 87 training labels.
By Zihan Ding, Liyu Zhang, Xiaomin Ouyang
AudioFuse is a hybrid architecture that jointly learns from spectrograms and raw waveforms to classify phonocardiograms. It combines a wide-and-shallow Vision Transformer for spectral features with a shallow 1D CNN for temporal waveforms, reducing overfitting while capturing complementary information. On the PhysioNet 2016 dataset, AudioFuse achieves a state‑of‑the‑art ROC‑AUC of 0.8608 and shows superior robustness to domain shift on the PASCAL dataset, outperforming both spectrogram‑only and waveform‑only baselines.
By Md. Saiful Bari Siddiqui, Utsab Saha
The paper benchmarks six long‑tail loss functions—cross‑entropy, weighted CE, class‑balanced loss, focal loss, LDAM, and logit‑adjusted softmax—across three single‑cell foundation model architectures (scGPT, scBERT, Geneformer) and three datasets (Multiple Sclerosis, Zheng68K, human Pancreas). It shows that overall accuracy masks systematic failures on rare, disease‑relevant cell types, with a consistent gap between overall accuracy, Macro‑F1, and rare‑class recall under plain cross‑entropy. The study identifies two distinct regimes of rare‑class failure, predicts reweighting efficacy by absolute training‑set size, and finds class‑balanced loss and LDAM to be the most reliable across all settings.
By Zeyu Dong, Jiahui Zhong
arXiv:2507. 12645v1 Announce Type: cross Abstract: The increasing need for accurate and unified analysis of diverse biological signals, such as ECG and EEG, is paramount for comprehensive patient assessment, especially in synchronous monitoring.
By Mohammed Guhdar, Ramadhan J. Mstafa, Abdulhakeem O. Mohammed
arXiv:2609.36848v1 Announce Type: new
Abstract: Human Activity Recognition (HAR) through wearable sensors greatly improves the quality of human life through its multiple applications. For HAR, multi-...
By Nafees Ahmad, Ho-fung Leung, Muhammad Adil Abid, Sadia Shakil
arXiv:2607. 27635v1 Announce Type: cross Abstract: Wearable sensors continuously capture fine-grained multivariate time-series data, providing opportunities to model behavioural patterns associated with health outcomes.
By Xiaotong Yu, Joshua Y. Kim, HaeJin Lee, Kalina Yacef