TCM-DiagCommit is a new benchmark derived from the TCM-SD/ZY-BERT dataset that expands 1,834 source cases into 23,842 task rows covering 148 syndrome labels. It evaluates models on three diagnostic behaviors—distinguishing semantic-neighbor syndromes, updating predictions as staged evidence (t1/t2/t3) is revealed, and committing under uncertainty—using a benchmark-defined action contract that scores commit, acquire, defer, and abstain. Experiments with five zero‑shot DirectLLM calibrations show that while random10 top‑1 accuracy ranges from 63.2% to 66.4%, performance drops sharply on harder subsets (hard20 and full148), highlighting that final‑answer accuracy alone is insufficient for diagnostic evaluation.
By Erwei Hou, Yue Hu
arXiv:2609. 31450v1 Announce Type: cross Abstract: Medical vision-language model (VLM) post-training is commonly evaluated through answer accuracy.
By Wang Jingxin
arXiv:2607. 01814v1 Announce Type: new Abstract: Traditional Chinese Medicine (TCM) diagnosis, particularly through tongue inspection, faces persistent challenges in subjectivity and reproducibility.
By Lihui Luo, Joongwon Chae, Ziyan Chen, Yang Liu, Siyi Cheng, Weihan Gao, Zelin Zeng, Xiaoming Yin, Samaneh Beheshti Kashi, Dongmei Yu, Lian Zhang, Jing Sui, Zeming Liang, Jiansong Ji, Peter E. Lobie, Peiwu Qin
The paper introduces MedQA-MM, a benchmark that exposes shortcut reasoning in medical multimodal multiple-choice questions. By auditing prompts, images, and modalities, the authors show that models often rely on textual cues rather than visual evidence, with full-input accuracy at 62.63% but only 5.21% when restricted to text. The study highlights the need for route-level evidence to validate true medical image reasoning.
By Benlu Wang, Yifan Zhang, Jiaqing Yu, Chin Siang Ong, Juncheng Huang, Zhuohao Li, Zhenyu Zhang, Arman Cohan, Hong Yu, Zonghai Yao
The paper introduces a Counterfactual Evidence Framework to evaluate medical vision‑language models (VLMs) by pairing lesion erasures with matched control edits, ring controls, and degraded views, thereby separating true visual discrimination from answer‑threshold shifts. Across 507 test cases, frontier VLMs correctly identify 41.1%–61.6% of erased lesions, while a counterfactual‑trained MedScope‑4B model achieves only 9.6%, with physician readers confirming the reliability of automated erasures in colonoscopy. The study also demonstrates that apparent utility gains stem from threshold adjustments rather than improved discrimination, and shows that retraining on pneumothorax cases can detect 53% of new pneumothoraxes without altering main‑test outcomes.
By Bhaskar Gurram
The paper introduces Evidence-Conditioned Dependency Distillation (ECDD), a method that trains compact medical vision‑language models to rely on visual evidence by pairing each training image with a control matched to the evidence level and distilling the teacher’s drop in answer margin across the pair. ECDD preserves task accuracy while making answer support more sensitive to evidence removal, outperforming standard knowledge distillation and alignment baselines in three medical VQA settings. The approach applies to various evidence types, such as clinical regions, surgical instruments, or whole‑image content.
By Qizhen Lan, Yiling Ma, Ruiqi Chen, Mengchen Fan, Xi Xiao, Lin Zhao, Liang He, Baocheng Geng, Pulin Che, Tianyang Wang, Xiaoqian Jiang
EviDent-CBCT is a framework that generates dental cone‑beam CT reports from limited clinical data by first extracting a discrete record of tooth‑level, global, and tooth‑IAC evidence using an anatomy‑aware network. The evidence is reconciled through a dental‑logic consistency projection before being rendered into a report by a deterministic renderer and an image‑blind language model. The system achieves higher evidence set‑F1 and logical‑F1 scores than baselines and ranked highly in the ODIN 2026 challenge, demonstrating the effectiveness of a discrete evidence record for auditable CBCT report generation.
By Ruiyang Hao, Zhi Qin Tan, Yulan He, Owen Addison, Yunpeng Li
MultiViewDx is a physician‑validated multimodal instruction dataset that links medical imaging studies with patient context and normalizes heterogeneous reports into an evidence‑linked workflow (evidence → findings → differential discussion → diagnosis). The dataset covers a wide range of imaging modalities and uses a unified image‑text retriever to ensure that instruction synthesis is grounded in source‑supported evidence. Fine‑tuned models on MultiViewDx achieve the highest average accuracy on four MedVQA benchmarks and receive the strongest overall rating on JAMA Clinical Challenge cases, with ablations confirming the importance of case‑level multi‑view organization and evidence‑linked reasoning.
By Junda Wang, Zonghai Yao, Yujan Ting, Eric Z. Chen, Hieu Tran, Hong Yu, Weijing Huang, Terrence Chen
arXiv:2609.39142v1 Announce Type: new
Abstract: Can structured text replace vision for diagram reasoning? A wrong answer after textualization can arise because the representation omits information th...
By Yunbei Zhang, Janet Wang, Jihun Hamm, Chandan K Reddy
The study evaluates four zero‑shot System 1 models on 86 public clinical tasks across 14 domains and 20 languages, measuring performance via AUROC. The best models achieved high AUROC scores—0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings, and 0.69 for volumetric findings—yet performed worse on imaging tasks and varied significantly with language. System 1 models were fast (0.34–0.44 s) and energy‑efficient (24–81 J) but lagged behind clinicians on triage and were outperformed by generative models in some metrics.
By Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik L\"ubberstedt, Johannes Moll, Anirudh Narayanan, Frederike Stumpf, Cosmin I. Bercea, Jiawen Wang, Evangelia E. Vassalou, Krischan Braitsch, Sebastian Ziegelmayer, Markus Graf, Marcus R. Makowski, Lisa Adams, Nassir Navab, Michail E. Klontzas, Keno Bressem
arXiv:2606. 00087v1 Announce Type: cross Abstract: Effective pre-polysomnography screening for obstructive sleep apnea-hypopnea syndrome (OSAHS) requires combining clinical risk factors with visible craniofacial and neck cues.
By Chen Zhan, Yingchen Wei, Xiaoyu Tan, Jingjing Huang, Xihe Qiu
arXiv:2610.38754v2 Announce Type: replace
Abstract: Knowledge-guided multimodal systems need a way to measure how supplied knowledge affects predictions, including when that knowledge is wrong. Alpha...
By Yucheng Liu, Everett X. Wang