arXiv Computer Vision

MedHarness: A Unified Budgeted Runtime for Reliable Medical Imaging Agents

MedHarness introduces a unified, budgeted runtime layer for medical imaging agents that allows a single shared controller to manage verification across multiple imaging surfaces. By attaching a shared decision object after an initial prediction, the system applies minimum‑sufficient verification, intermediate repair, and stop/open‑evidence decisions through surface‑specific adapters. Experiments on a 512‑case live pool show MedHarness reduces wrong accepts by ~47% and increases accepted accuracy to 83.2% while cutting remote service calls by ~71% compared to a full‑verification baseline.

arXiv AI
Oct 16

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

The paper introduces a benchmark of 400 synthetic healthcare workflow episodes to evaluate large language model (LLM) agents’ reliability in escalating care when evidence is missing or conflicting. It finds that while clean decision accuracy is high (0.97), models miss a large proportion of necessary escalations (32–97%) under uncertainty, and even the largest 9.7B model’s performance drops to 0.78 in conflict scenarios. A workflow-aware controller improves utility and reduces missed escalations, but its effectiveness is limited by lexical generalization failures.

By Zihao Zheng (Washington University in St. Louis), Junyi Yao (Washington University in St. Louis), Baichuan Li (Southern Methodist University), Jiayu Long (Washington University in St. Louis)
arXiv AI
Aug 12

CARE: Confidence-Aware Reasoning for Reliable Medical VQA

arXiv:2608. 10964v1 Announce Type: cross Abstract: Reinforcement Fine-Tuning (RFT) has enabled medical Multimodal Large Language Models (MLLMs) to produce Chain-of-Thought (CoT) reasoning for visual question answering, yet these models suffer from $\textit{confidence miscalibration}$---a systematic gap between expressed certainty and actual diagnostic accuracy that undermines clinical trust.

By Yuetian Du, Yucheng Wang, Zhenyuan Chen, Luyuan Chen, Rongyu Zhang, Jinjian Zhang, Wei Zhou, Zhijie Xu, Ming Kong, Zhan Zhou, Jie Liu, Qiang Zhu
arXiv AI
Aug 26

More Rejective, Not More Discriminative: The Unit of Verification in Pre-Execution LLM Oversight

The paper introduces the twin‑prefix framework to evaluate how the size of the verification unit—i.e., how many actions a pre‑execution LLM monitor reviews in one call—affects its performance. By pairing each gold plan with a twin that differs by a single write and injecting a controlled error, the authors isolate the impact of review length on catch rates and false rejections. Their findings show that longer review windows increase rejection rates but do not improve discrimination, with the highest informedness occurring at one or two actions across all judges and domains.

By Yuchen Han, Cheng Yan, Wuyang Zhang
arXiv Machine Learning
Oct 3

OmniMed-Jev: Calibrating LVLM Confidence for Trustworthy Medical Multimodal Decisions via System One

OmniMed-Jev is a new medical multimodal model that represents each decision as a Choice, Noul, or Score over a runtime-supplied candidate set, returning a full probability distribution for each decision. By unifying diverse imaging modalities and prediction tasks into a single candidate-conditioned probability model, it makes heterogeneous outputs comparable probabilities rather than task-specific strings. In controlled comparisons against a generative baseline, OmniMed-Jev’s reported probabilities align more closely with observed correctness, reducing calibration error by up to an order of magnitude and reliability error by up to two, while maintaining comparable point-prediction performance.

By Luyao Tang, Cheng Chen