arXiv:2608.24027v1 Announce Type: new
Abstract: 4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in a...
By Haojin Li, Hengzhuo Wang, Zhiheng Ma, Mingyang Ou, Heng Li, Jiang Liu
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
Accurate medical image interpolation and anatomical structure segmentation are fundamental for computer-aided diagnosis and treatment planning. Anisotropic medical volumes with sparse through-plane sampling often suffer from structural discontinuity and boundary blur, hindering reliable clinical image analysis.
arXiv:2606. 14759v1 Announce Type: cross Abstract: Cine cardiac magnetic resonance is the gold standard for assessing cardiac function, but the scarcity of public datasets limits the development of advanced data-driven models.
By Yiheng Cao (SyCoIA - IMT Mines Al\`es), Gustavo Andrade-Miranda (SyCoIA - IMT Mines Al\`es), Jiatian Zhang, Guillaume Sall\'e, Xin Gao
The paper introduces a geometry‑guided sampling operator that directs feature sampling rather than altering convolution kernels in 3D encoder‑decoder networks. By predicting local orientations and bounded step sizes, the operator samples symmetrically around each voxel, generating compact geometric and boundary cues that improve fine‑structure segmentation. Replacing stride‑1 and stride‑2 operations in a 3D U‑Net yields consistent gains on BraTS, MSD Hepatic Vessel, and TDSC‑ABUS datasets, with better boundary metrics and fewer parameters, and the operator can be integrated into other backbones without architectural changes.
By Sizhe Wang, Himashi Peiris, Zhaolin Chen
arXiv:2607. 02564v1 Announce Type: cross Abstract: Computational models of the human heart are widely used to study electromechanical and fluid-dynamical cardiac function and to support applications such as in silico clinical trials.
By Francesco Fabbri, Martino Andrea Scarpolini, Paolo Ciancarella, Francesco Tudisco, Roberto Verzicco, Alessandro Ricci, Francesco Viola
arXiv:2608. 19965v1 Announce Type: cross Abstract: Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology.
By Sidi Mohamed Sid'El Moctar, Nicolas Vitry, H\'el\`ene Bouvrais
arXiv:2608.20942v1 Announce Type: new
Abstract: Motivated by the classical Chan-Vese model and the ability of deep priors to capture complex spatial structures, we develop a segmentation model that l...
By Shuangshuang Duan, Chunlei He, Shoujun Huang, Dexing Kong
FlowMoDL is an unrolled neural network designed for highly accelerated 4D flow MRI reconstruction, optimizing both anatomical magnitude and phase-derived velocity accuracy. It alternates a learned (3+1)D spatiotemporal denoiser with conjugate‑gradient data‑consistency updates, using a dual‑pathway conditioning scheme to handle acceleration factors from 10× to 50×. Trained with a deep‑supervision composite loss that penalizes velocity magnitude and angular errors, FlowMoDL outperforms classical and deep‑learning baselines on the multi‑center CMRx4DFlow dataset, achieving superior gradient‑step efficiency and robust convergence across all acceleration factors.
By Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber, Daniel Tenbrinck, Torsten Panholzer, Melanie Schaller, Jana Hutter
arXiv:2505. 17338v3 Announce Type: replace-cross Abstract: Photorealistic volumetric rendering of CT scans greatly benefits clinical workflows, yet neural approaches such as Neural Radiance Fields (NeRF) and 3D Gaussian Splatting (3DGS) require prohibitive per-scan optimization (hours for NeRF, about 30 minutes for 3DGS), making them impractical in clinical settings.
By Zhongpai Gao, Benjamin Planche, Meng Zheng, Anwesa Choudhuri, Van Nguyen Nguyen, Terrence Chen, Ziyan Wu
arXiv:2605. 00941v5 Announce Type: replace Abstract: Flow matching provides a highly effective framework for generative modeling, yet estimating the uncertainty of its generated samples remains a fundamental challenge.
By Jiarui Xing, Song Wang, Jian Wang