NV-Reason-CT is a generative vision‑language model designed for chest and abdominal CT analysis that preserves native 3D visual encoding and incorporates radiologist‑guided reasoning. The system couples a 3D vision transformer with a language model, feeding all visual tokens and their 3D coordinates directly into language decoding to maintain volumetric spatial information. Trained on a curated corpus of about 550,000 multimodal instruction examples, the model supports abnormality classification, report generation, and interactive reasoning, achieving strong performance on CT benchmarks and reducing expert interpretation time by 50%.
By Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon, Stephanie Harmon, Rikhil Makwana, Mariam Aboian, Sena Azamat, Ibrahim Ethem Hamamci, Sezgin Er, Bjoern Menze, Marc Edgar, Yufan He, Pengfei Guo, Daguang Xu
arXiv:2607. 27154v1 Announce Type: cross Abstract: CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals.
By Roshan Kenia, Stephanie L McNamara, William Lotter
The paper introduces a 3D-CLIP encoder trained with structured hard negatives to improve vision‑language alignment for text‑to‑CT generation. This encoder drives a latent diffusion model that operates directly in 3D latent space, eliminating spatial artifacts from super‑resolution pipelines. Experiments on the CT‑RATE dataset show state‑of‑the‑art image fidelity and factual correctness across 18 pathological conditions, with lower inference time and GPU memory usage than competing methods.
By Daniele Molino, Camillo Maria Caruso, Filippo Ruffini, Paolo Soda, Valerio Guarrasi
arXiv:2510. 15042v3 Announce Type: replace-cross Abstract: In the 3D medical image domain, vision-language pre-training is used to create vision-language encoders (VLEs) that can support radiologists by retrieving patients with similar abnormalities, predicting likelihoods of abnormality, or, with downstream adaptation, generating radiological reports.
By Tassilo Wald, Ibrahim Ethem Hamamci, Yuan Gao, Sam Bond-Taylor, Harshita Sharma, Maximilian Ilse, Cynthia Lo, Olesya Melnichenko, Anton Schwaighofer, Noel C. F. Codella, Maria Teodora Wetscherek, Klaus H. Maier-Hein, Panagiotis Korfiatis, Valentina Salvatelli, Javier Alvarez-Valle, Fernando P\'erez-Garc\'ia
arXiv:2607. 27154v2 Announce Type: replace-cross Abstract: CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals.
By Roshan Kenia, Stephanie L McNamara, William Lotter
arXiv:2506. 00633v3 Announce Type: replace-cross Abstract: Generating semantically controllable 3D CT volumes from radiology reports requires more than a rich text encoder, it requires vision-language alignment grounded in volumetric space.
By Daniele Molino, Camillo Maria Caruso, Filippo Ruffini, Paolo Soda, Valerio Guarrasi
arXiv:2610.06896v1 Announce Type: new
Abstract: Frontier multimodal large language models (MLLMs) are increasingly positioned as general purpose visual reasoners as part of the quest for artificial g...
By Ross Callaghan, Niannu Gao, Hojjat Azadbakht, Hui Zhang
arXiv:2608.00239v2 Announce Type: replace
Abstract: Learning transferable representations from CT-report pairs requires combining whole-volume context with anatomy-specific evidence. Existing methods...
By Guoliang You, Haifan Gong, Xiaomeng Chu
arXiv:2601.09879v2 Announce Type: replace-cross
Abstract: Recent progress in medical vision-language models (VLMs) has achieved strong performance on image-level text-centric tasks such as report gen...
By Yang Xing, Jiong Wu, Savas Ozdemir, Ying Zhang, Yang Yang, Wei Shao, Kuang Gong
arXiv:2509.22404v2 Announce Type: replace
Abstract: Anatomical understanding, which is the ability to identify, localize, or segment anatomical structures, is critical in medical image analysis; howe...
By Yiwei Li, Yikang Liu, Jiaqi Guo, Lin Zhao, Zheyuan Zhang, Xiao Chen, Boris Mailhe, Ankush Mukherjee, Terrence Chen, Shanhui Sun
The study fine‑tunes a pretrained 3D medical vision‑language model for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution. Two adaptation strategies—full fine‑tuning and parameter‑efficient fine‑tuning (PEFT)—both achieve strong performance (AUC 0.82/0.79, F1 0.71/0.70) despite cross‑institutional domain shift, with PEFT updating only ~1% of parameters. The work highlights the trade‑offs between rapid convergence and overfitting in full fine‑tuning versus the efficiency of PEFT, and shows that self‑supervised CT‑report contrastive learning can improve HCC classification without lesion‑level annotations.
By Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
Medical vision-language models (VLMs) have shown increasing potential for clinical image interpretation. However, these models still struggle to interpret multi-phenotype lesions whose diagnosis requi...