arXiv:2606. 17710v1 Announce Type: cross Abstract: Medical vision-language models report strong chest radiograph accuracy, and this is increasingly read as evidence that they use the image.
By Mahshad Lotfinia, Sebastian Ziegelmayer, Lisa Adams, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh
The study evaluates four zero‑shot System 1 models on 86 public clinical tasks across 14 domains and 20 languages, measuring performance via AUROC. The best models achieved high AUROC scores—0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings, and 0.69 for volumetric findings—yet performed worse on imaging tasks and varied significantly with language. System 1 models were fast (0.34–0.44 s) and energy‑efficient (24–81 J) but lagged behind clinicians on triage and were outperformed by generative models in some metrics.
By Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik L\"ubberstedt, Johannes Moll, Anirudh Narayanan, Frederike Stumpf, Cosmin I. Bercea, Jiawen Wang, Evangelia E. Vassalou, Krischan Braitsch, Sebastian Ziegelmayer, Markus Graf, Marcus R. Makowski, Lisa Adams, Nassir Navab, Michail E. Klontzas, Keno Bressem
The paper introduces a Counterfactual Evidence Framework to evaluate medical vision‑language models (VLMs) by pairing lesion erasures with matched control edits, ring controls, and degraded views, thereby separating true visual discrimination from answer‑threshold shifts. Across 507 test cases, frontier VLMs correctly identify 41.1%–61.6% of erased lesions, while a counterfactual‑trained MedScope‑4B model achieves only 9.6%, with physician readers confirming the reliability of automated erasures in colonoscopy. The study also demonstrates that apparent utility gains stem from threshold adjustments rather than improved discrimination, and shows that retraining on pneumothorax cases can detect 53% of new pneumothoraxes without altering main‑test outcomes.
By Bhaskar Gurram
Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative la...
The ReXGrounding Challenge, held at MICCAI 2026, focused on segmenting radiology findings in 3D chest CT scans based on report text. Using the ReXGroundingCT dataset, 48 teams from 15 countries submitted 760 models, with the best achieving a Dice score of 0.375 and a hit rate of 0.77—comparable to inter‑radiologist agreement. Despite this progress, challenges remain for non‑focal findings, multi‑instance cases, and accurate anatomical localization.
By Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens, Zirong Chen, Jiayu Wang, Xi Ouyang, Mingyang Yu, Weiqiu Jin, Xiaodan Ye, Dijia Wu, Kwang-Hyun Uhm, Inhwa Son, Rachel van 't Hull, Tim Veenboer, Cees Snoek, Kevin Groot Lipman, Daesung Kim, Junha Im, Youngjun Jun, Sangwon Lee, Katelyn Morrison, Adam Perer, Mijin Yun, Ali Piracha, Reem Alwasiah, Talal Yahyan, Abdulrahman Alamoudi, Mashael Alshehri, Rayan Alsager, Hannah Hancock, Anna M. Hunkem\"oller, Peter Youssef, Mona A. Alhammad, Afnan Aljumayan, Brecht Van Berkel, Eric Bijnens, Saud Alhussain, Maarten Steyvers, Rolf Symons, Bryan Eelen, Ayed Alaklubi, Maha Buraykan Alshammari, Amirah Fahad Alshammeri, Tomas Gilvydis, Ibrahim AlTurki, Monerah Almohideb, Ali Alburkani, Shahad Alhomaiani, Fatima Jabali, Maximilian Rokuss, Moritz Langenberg, Yannick Kirchhoff, Benjamin Hamm, Klaus Maier-Hein, Ibrahim Ethem Hamamci, Sezgin Er, Michael Moritz, Hassan R. Alomaish, Luyang Luo, Pranav Rajpurkar
The study introduces Safety-Focused Evaluation of Scaling (SaFE-Scale) and applies it to RadSaFE-200, a 200-question radiology benchmark with clinician-defined evidence and safety labels. Thirty-four local large language models were tested under six deployment conditions, showing that providing clean clinician-written evidence significantly improved accuracy and reduced high-risk errors and dangerous overconfidence. The results indicate that safety in clinical LLMs depends more on deployment choices than on model size or inference-time compute.
By Sebastian Wind, Tri-Thien Nguyen, Jeta Sopa, Mahshad Lotfinia, Sebastian Bickelhaup, Michael Uder, Harald K\"ostler, Gerhard Wellein, Sven Nebelung, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh
arXiv:2608. 07550v1 Announce Type: cross Abstract: Vision-language models return structured chest-radiograph findings through interfaces exposing no confidence score, so a receiving institution cannot read off how far to trust an individual judgment.
By Pengyang Yu, Yiou Wang, Zhongping Dong, Sahraoui Dhelim, Chun-Mei Feng, M. Tahar Kechadi
arXiv:2610.17989v1 Announce Type: cross
Abstract: A medical vision-language model may analyze a given CT scan and correctly detect both kidneys in view. Continuing this conversation, if a user provid...
By Sadif Ahmed, Soumya Swagata Biswas, Rifat Shahriyar, Chowdhury Mohammad Rakin Haider
arXiv:2610.15239v1 Announce Type: new
Abstract: Most benchmarks for large language models in medicine are built from licensing examinations and theoretical questions. The few that draw on real clinic...
By Anurag Sharma, Aditya Sharma, Sapna Baalwan
A medical vision-language model may analyze a given CT scan and correctly detect both kidneys in view. Continuing this conversation, if a user provides a prescription with an opposite direction, medic...
arXiv:2610.32478v1 Announce Type: new
Abstract: Vision-language models used for decisions in histopathology rarely return calibrated probabilities over the candidates a user cares about. Decision-nat...
By Cristian Tommasino, Antonio M. Rinaldi
The study evaluated the accuracy and calibration of several Decision and System One models on rheumatology specialty‑training exam questions and diagnostic vignettes. On the RheumaMIR exam dataset, Jev achieved 93.0% accuracy in Spanish and 91.9% in English, while GPT‑6 Sol reached 99.4%. On the RheumBench diagnostic vignettes, GPT‑6 Sol again led with 76.9% accuracy, with Jev and other System One models scoring significantly lower (50.0%–59.6%).
By Alfredo Madrid-Garc\'ia, Diego Benavent, Fabian Lechner, Phillip Kremer, Johannes Knitza, Beatriz Merino-Barbancho