arXiv:2607. 24553v1 Announce Type: cross Abstract: Standardized echocardiography conclusions provide meaningful supervision for learning ECG representations of echocardiography-derived cardiac findings.
By Xiaocheng Fang, Jieyi Cai, Guangkun Nie, Haoyu Wang, Jiarui Jin, Yujie Xiao, Bo Liu, Chenyang He, Qinghao Zhao, Gaofeng Cheng, Hongyan Li, Shenda Hong
arXiv:2607. 15928v1 Announce Type: new Abstract: Adult and pediatric electrocardiogram (ECG) interpretation relies on age-sensitive criteria, and models pretrained mainly on adult ECGs often transfer poorly to pediatric populations when pediatric labels are scarce.
By Xinran Liu, Yuwen Li, Hongxiang Gao, Heyang Xu, Jianqing Li, Zongmin Wang, Chengyu Liu
arXiv:2605. 00647v2 Announce Type: replace Abstract: Automated pediatric electrocardiogram (ECG) interpretation remains challenging because developmental differences in heart rate, intervals, and waveforms limit the transferability of models trained mainly on adult data, while expert-labeled pediatric ECG cohorts are scarce.
By Xinran Liu, Yuwen Li, Hongxiang Gao, Heyang Xu, Jianqing Li, Zongmin Wang, Chengyu Liu
arXiv:2603. 08505v2 Announce Type: replace-cross Abstract: Electrocardiography (ECG) is a low-cost, widely used modality for diagnosing electrical abnormalities like atrial fibrillation by capturing the heart's electrical activity.
By Michelle Espranita Liman, \"Ozg\"un Turgut, Alexander M\"uller, Eimo Martens, Daniel Rueckert, Philip M\"uller
arXiv:2607. 16323v1 Announce Type: cross Abstract: Electrocardiography (ECG) is an inexpensive, standard-of-care test for cardiac symptoms, but front-line triage often lacks immediate access to definitive imaging such as echocardiography (ECHO) or cardiac magnetic resonance (CMR).
By Alexander Selivanov, Friederike Jungmann, Jan Kehrer, Karl-Ludwig Laugwitz, Eimo Martens, Daniel Rueckert
arXiv:2608. 05893v1 Announce Type: new Abstract: Electrocardiography (ECG) is one of the most widely used non-invasive tools for diagnosing cardiovascular disease, but transforming multi-lead ECG recordings into reliable clinical reports remains challenging.
By Akanta Das, Tasinul Islam Ahon, Ahmed Mahir Sultan Rumi, Md Mahbubur Rahman, Tausif Amim Shadly, Tanzima Hashem
Echo-E$^3$Net is an anatomy‑guided spatio‑temporal neural network designed to estimate left ventricular ejection fraction (LVEF) from ultrasound images. It uses a dual‑phase Endocardial Border Detector to locate end‑diastole and end‑systole landmarks and an Endocardial Feature Aggregator to fuse these landmarks with global deep‑feature descriptors for EF regression. The model achieves competitive accuracy on EchoNet‑Dynamic and EchoNet‑Pediatric datasets while using only 1.55 M parameters and 8.05 GFLOPs, enabling real‑time deployment on limited‑resource devices.
By Moein Heidari, Afshin Bozorgpour, AmirHossein Zarif-Fakharnia, Wenjin Chen, Dorit Merhof, David J. Foran, Jasmine Grewal, Ilker Hacihaliloglu
The paper introduces ORBIT, a self‑supervised method for detecting end‑diastolic and end‑systolic cardiac phases in fetal echocardiography without manual annotations. ORBIT learns a latent motion trajectory through registration, enabling orientation‑robust identification of phase transitions across diverse fetal heart positions. Evaluated on normal and congenital heart disease cases, it achieves low mean absolute errors (≈1.9–2.4 frames) and outperforms prior annotation‑free approaches that assume fixed orientations.
By Yingyu Yang, Qianye Yang, Can Peng, Elena D'Alberti, Olga Patey, Aris T. Papageorghiou, J. Alison Noble
arXiv:2607. 14613v1 Announce Type: cross Abstract: Long-tailed label distributions reduce the reliability of deep learning for electrocardiogram (ECG) arrhythmia diagnosis, particularly for clinically important but rare abnormalities.
By Jin Dai, Qiuzhen Zhang, Chenyun Dai, Danmei Lan, Can Han
arXiv:2608. 12944v1 Announce Type: new Abstract: Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited.
By Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu, Aaqib Saeed
arXiv:2606. 15284v1 Announce Type: cross Abstract: Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support.
By Chenyang He, Xinyi Shao, Shun Huang, Bosong Huang, Daoqiang Zhang, Ming Jing, Cheng Ding
arXiv:2607. 01039v1 Announce Type: cross Abstract: Therapy-induced cardiotoxicity is the leading non-oncological cause of treatment interruption in breast cancer patients, yet early, automated risk stratification from routine cardiac imaging remains an unsolved problem.
By Grigorios Kalliatakis, Georgia Karanasiou, Georgios Manikis, Manolis Tsiknakis, Dimitrios Fotiadis, Dorothea Tsekoura, Kalliopi Keramida, Vasileios Bouratzis, Lampros Lakkas, Katerina Naka, Andri Papakonstantinou, Anastasia Constantinidou, Kostas Marias