arXiv:2606. 31349v1 Announce Type: cross Abstract: Surface electromyography (sEMG)-based gesture recognition has emerged as a promising technology for natural human-computer interaction.
By Yurui Liu, Xiao-Cong Zhong, Qisong Wang, Xuefu Wang, Dan Liu, Jinwei Sun
arXiv:2607. 03783v1 Announce Type: new Abstract: Cross-subject generalization remains a fundamental challenge in surface electromyography (sEMG)-based gesture recognition.
By Hamed Rafiei, Ali Mousavi
arXiv:2609.25582v1 Announce Type: new
Abstract: Public surface electromyography (EMG) datasets vary widely in electrode layout, channel count, frequency support, and size. Simply mixing them for pret...
By Yuwei Jia, Cheng Zhong, Jinyang Yu, Zhe Cui
arXiv:2601. 17883v3 Announce Type: replace Abstract: Electroencephalography (EEG) foundation models (FMs) have recently emerged as a promising paradigm for brain-computer interfaces, aiming to learn transferable neural representations from large-scale heterogeneous recordings.
By Dingkun Liu, Yuheng Chen, Zhu Chen, Zhenyao Cui, Yaozhi Wen, Jiayu An, Jingwei Luo, Dongrui Wu
EMG-FM-Bench is a benchmark that unifies 20 public electromyography datasets, totaling over one million EMG segments, to evaluate how foundation models transfer and adapt to EMG tasks. It tests nine pretrained models across four scenarios: frozen versus fully fine‑tuned performance, the benefit of pretraining versus training from scratch, generalization to new users with limited data, and performance across different EMG tasks. Results show that linear probing reveals useful pretrained representations, full fine‑tuning can significantly alter performance, pretraining benefits vary by model, performance drops on new users, and few‑shot adaptation improves macro‑F1 in most cases but only partially recovers lost performance.
By Tianhao Wu, Jiawei Yu, Xiangdong Hu, Xu Wu, Hongyu Wu, Sidharth Anupkrishnan, Amirmohammad Radmehr, Yi Chen Liu, Phuc Nguyen, Yi Wu, Jian Liu
The paper investigates how to adapt recurrent neural networks for surface electromyography (sEMG) gesture recognition across different users and new gesture classes using continual learning (CL). Three CL strategies—experience replay, elastic weight consolidation (EWC), and naive fine‑tuning—were evaluated on the NinaPro DB1 dataset under domain‑ and class‑incremental drift, with experience replay achieving the highest final accuracy (83.3%) and the lowest forgetting (1.8–5.8%). The study also shows that training on shuffled, independently‑windowed segments and incorporating hand‑crafted time‑domain features can significantly improve per‑task accuracy, but only experience replay maintains this advantage under class‑incremental drift.
By Aran Ramakrishnan, Shubhi Mishra, Tyler Ham, Assel Kembay, Jason Eshraghian
MyoFlow introduces a discriminative flow-matching framework for high‑density surface electromyography (HD‑sEMG) gesture recognition that addresses distribution shifts caused by electrode re‑donning and physiological variability. By using a domain‑conditioned rectified flow to transport encoded windows toward gesture anchors, the method enables zero‑shot prediction without a separate classifier head. On the Hyser dataset, MyoFlow outperforms the strongest diffusion‑based baseline by 4.24 % in cross‑session accuracy and 6.37 % in cross‑subject accuracy, and achieves 91.71 % mean zero‑shot accuracy and 97.39 % mean few‑shot accuracy on the CEMHSEY dataset.
By Chenhao Wu, Dingjie Peng, Satoshi Funabashi, Satoshi Konishi, Wuqiang Yang, Hiroshi Onoda, Hironori Washizaki, Jiang Liu
The paper introduces a Cross-Subject Perceived Speech Decoding (CPSD) framework that tackles the challenge of decoding perceived speech from non‑invasive brain recordings across different subjects. CPSD uses a two‑stage training process: first, contrastive learning pre‑trains a source model on multiple subjects to capture shared representations; second, personal specialization fine‑tunes the model for a target subject by extracting consistent components and further training on that subject’s data. A Positional Encoding‑based Spatial Attention (PESA) module is added to remap MEG/EEG data into a standardized reference space, improving cross‑subject consistency. Evaluations on three datasets (Armeni 2022, PKUEEG 2025, Broderick 2018) show that CPSD outperforms baseline methods by more than 6.8%, 15.4%, and 15.8% in Top‑10 accuracy, demonstrating its effectiveness, efficiency, and robustness.
By Aoke Zhang, Bo Wang, Xihong Wu, Heping Cheng, Jing Chen
arXiv:2611.27415v1 Announce Type: new
Abstract: Co-speech gesture detection identifies the spans in which a speaker gestures (e.g., beat or semantic gestures) in video. As a first step in gesture ann...
By Frances Yung, Ninlawat Phuangschoke
arXiv:2601. 04181v2 Announce Type: replace Abstract: Reliable long-term decoding of gestures from surface electromyography (EMG) is hindered by signal drift caused by electrode displacement, muscle fatigue, and/or posture changes.
By Nia Touko, Matthew O A Ellis, Cristiano Capone, Alessio Burrello, Elisa Donati, Luca Manneschi
arXiv:2607. 27568v1 Announce Type: new Abstract: Recognition accuracy obtained during a recording session does not persist when a user puts on the electrodes again after the electrodes had previously been removed.
By Jethro Odeyemi, W. J. Zhang
Pattern-recognition control promises a myoelectric prosthesis that responds to many intended gestures rather than one or two, but the promise has stayed in the laboratory. A recogniser trained on one person rarely transfers to the next, and useful performance usually demands a fresh round of labelled calibration from the end user.