arXiv:2610.15702v1 Announce Type: cross
Abstract: Respiratory auscultation provides a low-cost means of assessing pulmonary function, yet transient crackles and sustained wheezes can be difficult to...
By Yi Tian, Xiaohuan Chen, Yufei tang, Xinyu Lin, Hongliang Li, Chengbin Hou, Degen Huang, Rongshan Yu
arXiv:2606. 26723v1 Announce Type: cross Abstract: Respiratory activity is a direct and interpretable physiological channel for wearable stress and affective-state recognition, yet many studies emphasize classification accuracy without identifying which respiratory properties separate different states.
By Andrei Velichko, Mehmet Tahir Huyut
BreathGRU is a semi‑supervised Bidirectional Gated Recurrent Unit framework designed to segment speech and breath events in respiratory audio. It combines acoustic feature extraction, bidirectional recurrent modeling, pseudo‑label refinement, and duration‑constrained Segmental Viterbi decoding to produce accurate speech‑breath segmentation. In evaluations against existing methods, BreathGRU achieved the highest breath event recall, lowest onset‑localisation error, and highest Mean Match Intersection over Union, outperforming large pretrained VAD models such as Silero.
By Sania Fatima Sayed, John W. Holloway, Reyer Zwiggelaar, Faisal I. Rezwan
Apnoea of prematurity is characterised by recurrent episodes of cessation of breathing and remains difficult to detect reliably using routinely monitored physiological signals in the Neonatal Intensive Care Unit (NICU). Existing bedside monitors rely primarily on respiratory rate and oxygen saturation thresholds, often generating high false-positive alarm rates and missing short or irregular events.
Breath‑Dx is a new benchmark for time‑series classification in disease screening using electronic nose (eNose) data, built on the Scent of Health (S‑OH) dataset of 1,234 patients across nine diagnostic groups. It evaluates ten machine‑learning methods—including feature‑based, convolutional, graph‑based, and time‑series models—under realistic temporal validation that accounts for sensor drift, revealing significant performance drops (0.05–0.12 AUC) compared to random cross‑validation. The benchmark shows recurrent architectures perform consistently, while specialized time‑series models achieve the highest peak AUCs (0.74–0.76) for certain lung conditions, and highlights the role of demographic confounders in diagnostic value.
By Ivan Poddiakov, Ivan Kruzhilov, Galina Zubkova, Svetlana Erofeeva, Andrey Savchenko, Pavel Blinov
The paper introduces a non‑invasive method for detecting respiratory phases using acoustic recordings from standard smartphones. It employs a hybrid CNN‑Transformer model that captures both local spectral features and long‑range temporal patterns, achieving high accuracy in both frame‑level and cycle‑level evaluations on a large, independent test set. An ONNX deployment pipeline allows real‑time, privacy‑preserving inference on mobile and wearable devices with sub‑20 ms latency.
By Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero