arXiv:2608. 12944v1 Announce Type: new Abstract: Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited.
By Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu, Aaqib Saeed
The study investigates how adding ballistocardiography (BCG) signals to photoplethysmography (PPG) and arterial pressure wave (APW) signals affects the estimation of cardiovascular biomarkers. Using a unified whole‑body cardiovascular model, synthetic PPG, APW, and BCG signals were generated and analyzed with neural posterior estimation and simulation‑based inference. Results show that incorporating BCG significantly improves estimation accuracy, converting multimodal posterior distributions from PPG/APW alone into unimodal distributions, thereby enhancing the reliability of cardiovascular biomarker estimation.
By Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi, Kunio Kashino
arXiv:2608. 14763v1 Announce Type: cross Abstract: Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement.
By Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant, Davood Karimi
The paper presents a hybrid Transformer framework that estimates non‑invasive continuous blood pressure from ECG/PPG‑derived feature sequences. It models 10‑step sequences of six physiological descriptors and two demographic covariates, combining Transformer, Kolmogorov‑Arnold Network, and XGBoost modules, and uses a dynamic fusion decoder to predict diastolic and systolic BP. On a large MIMIC‑III dataset, the model achieved mean errors of 0.41 mmHg (diastolic) and –1.60 mmHg (systolic) with high accuracy within 10 mmHg for most predictions.
By Yuexin Ma, Jingqi Hou, Yuxuan Kang, Zhaoying Liu
Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fus...
CardioFusion-AI is a framework for robust fusion of ECG and PPG signals in wearable physiological monitoring. Its signal‑processing front end, featuring R‑peak and systolic‑peak detection, an Orphanidou‑type signal‑quality index, and beat‑by‑beat pulse transit time estimation, was validated on 53 intensive‑care recordings and a fetal ECG database. In a controlled synthetic degradation study, attention fusion achieved the lowest overall error, while adaptive gates reallocated weight toward the healthy modality under complete loss, and signal‑quality conditioning improved performance when PPG was missing.
By Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan