FETALFusion is a dual‑path CNN‑Mamba encoder‑decoder designed for fetal head segmentation in 2D ultrasound across transabdominal and transperineal acquisition types. It uses four‑directional state‑space scans at the highest‑resolution stages, domain‑specific channel gates, and a weak landmark shape prior, achieving a Dice score of 0.963 and an HD95 of 2.10 mm on a held‑out test set of 471 images. Ablation studies show that the landmark prior and domain gates drive most of the performance gains, while the state‑space branch has minimal impact.
whyItMatters":"The method provides highly accurate fetal head segmentation without test‑time augmentation or domain labels, enabling reliable head circumference measurement for monitoring fetal growth."
By Ammar Bhilwarawala, Mainak Bandyopadhyay
arXiv:2608. 04766v1 Announce Type: cross Abstract: A large number of infants with congenital anomalies are born each year globally, especially in areas with underdeveloped medical resources.
By Bin Pu, Jiewen Yang, Liwen Wang, Ying Tan, Guannan He, Xingbo Dong, Qika Lin, Jiarong Guo, Lixian Yang, Zuozhu Liu, Shengli Li, Kenli Li
The paper introduces SonoCorpus, an open dataset of 456,963 ultrasound images with 1,626,085 expert masks from 53 public sources across 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on this data. SonoBase outperforms existing models (SAM2, MedSAM2, MedSAM3) on fifteen diverse evaluation datasets, matching specialist models and achieving clinically relevant accuracy for metrics such as ejection fraction, fetal head circumference, and gestational age. The authors provide full reproducibility resources, including checkpoints, optimizer states, and starter code, to enable community adoption and further development.
By Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar, Rao Muhammad Anwer, Shadab Khan
This study introduces a pipeline that enhances ultrasound plane pose estimation for fetal brain imaging by providing continuous, real‑time proximity feedback to standard planes (SPs). It employs a semi‑supervised segmentation model achieving high mIoU scores on both SPs and non‑SPs, and integrates a classification step to filter out frames without the fetal brain. The system, validated on an NVIDIA Clara AGX edge device, runs at 39 Hz and has been tested on real scan videos from 17 sonographers, demonstrating its practical viability for clinical use.
By Chiara Di Vece, Antonio Cirigliano, Meala Le Lous, Raffaele Napolitano, Anna L. David, Donald Peebles, Pierre Jannin, Francisco Vasconcelos, Danail Stoyanov
arXiv:2606. 29586v1 Announce Type: cross Abstract: Vision-language foundation models have shown strong potential in medical image analysis.
By Hang Su, Chao Sun, Zhaofan Li, Wei Hu, Juhua Liu, Bo Du
arXiv:2606. 11106v1 Announce Type: cross Abstract: A global shortage of trained sonographers limits prenatal ultrasound screening in low- and middle-income countries, where over half of pregnant women receive no skilled sonography.
By Mahmood Alzubaidi, Uzair Shah, Raden Muaz, Ines Abbes, Nader Mohammed, Abdullatif Magram, Khalid Alyafei, Mowafa Househ, Marco Agus