TAPCO-G is a post-placement timing and power co‑optimization framework that uses a large language model (LLM) to adapt repair policies and graph‑based physical priors to evaluate cell replacement candidates. It employs an outer loop that tunes tool settings with physical‑design feedback and an inner loop that anchors delay estimates to static timing analysis snapshots, propagates delay shifts, and performs coarse‑to‑fine power screening. On eight ASAP7 benchmarks from the MLCAD 2026 Contest, TAPCO‑G produced placement‑legal, logic‑equivalent implementations and outperformed CERBERUS and TAPCO, achieving a mean quality score gain of 5.516 points and scoring 21.648 points higher on average.
By Wuqian Tang, Zixiao Wang, Che-Chien Lin, Fong-Hua Fu, Laura Ang\'elica Shion-Korsak, Xinyun Zhang, Bei Yu, Chun-Yao Wang
arXiv:2609.23444v1 Announce Type: cross
Abstract: Engineering change order (ECO) is an important step in repairing timing and electrical violations during the late stages of chip design. Existing Age...
By Guoxiang Xu, Guozhen Ji, Zijian Luo, Zhengrui Chen, Qi Sun, Cheng Zhuo
arXiv:2608. 08048v1 Announce Type: cross Abstract: This paper presents, for the first time in power systems literature to our knowledge, analytical tools to explain the training performance of machine learning surrogate models for power system dynamics.
By Petros Ellinas, Johanna Vorwerk, Spyros Chatzivasileiadis
arXiv:2605. 06936v3 Announce Type: replace-cross Abstract: LLM-based agents are increasingly applied to the "last mile" of Electronic Design Automation (EDA): repairing residual sign-off Design Rule Check (DRC) violations and converging Power-Performance-Area (PPA) targets after tool runs.
By Pengju Liu, Nuo Xu, Jinwei Tang, Yu Cao, Caiwen Ding
EvEMTBench is an open, executable, and versioned benchmark designed to standardize the evaluation of machine‑learning methods for power system protection. It defines 12 protection and event‑analysis functions across four grids (20–345 kV) as 24 scored tasks, enabling structured assessment under varied observability, distribution shifts, and cross‑grid transfer scenarios. The benchmark includes committed data partitions, leakage controls, and reproducible reporting, and demonstrates that wider observability does not always help, that shifted conditions expose hidden failures, and that fault detection transfers better than fault localization.
By Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
arXiv:2605.31478v2 Announce Type: replace-cross
Abstract: Large language models (LLMs) can turn grid-analysis requests into executable programs for power-system simulation, but utilities and research...
By Hui Wu, Xiaoyang Wang, Zhong Fan