Using AI to mitigate the growing environmental threat of data centers
By rethinking how large cloud computing systems operate, Associate Professor Christina Delimitrou seeks to make data centers more energy efficient.
Founded by two researchers from MIT, Ferveret reduces the amount of energy and water required to cool the chips that power AI.
By rethinking how large cloud computing systems operate, Associate Professor Christina Delimitrou seeks to make data centers more energy efficient.
The paper introduces a new EnergyPlus object, ElectricEquipment:ITE:LiquidCooled, that models direct-to-chip liquid cooling for both chilled‑water and warm‑water data center architectures. Validation against a Modelica implementation shows temperature errors below 0.021 K across 21 operating conditions, meeting the 0.1 K threshold. A case study indicates that warm‑water cooling can lower annual PUE from 1.43 to 1.25, eliminate on‑site water use, and cut total facility energy by 37.9% compared to an air‑cooled baseline.
The paper introduces an AI-driven framework for thermal‑aware capacity planning in data centers, enabling temperature predictions in milliseconds by learning from key parameters such as rack power, server placement, and HVAC settings. The model is validated against high‑fidelity CFD simulations and achieves a 10,000‑fold speedup while maintaining high accuracy for unseen designs. This rapid prediction capability allows designers and operators to instantly optimize workload distribution and cooling efficiency.
The paper reviews 194 papers on using artificial intelligence to optimize data center energy use, coding 63 of them. It finds that most control studies validate only in simulation, none consider water withdrawal or embodied carbon, and savings estimates overlap across methods, preventing ranking. The authors propose CLEAR‑DC, a framework that links control and workload demand through elasticity, reports net benefits, and records energy, carbon, water, embodied share, and validation venue.
The paper presents an LLM-based predictive scheduling system that forecasts execution time and energy consumption from source code, aiming to improve data center sustainability. By integrating these predictions into a real-time GPU allocation algorithm, the system reduces both energy use and queuing delays. In a collaboration with a data center, the approach achieved a 32% drop in energy consumption and a 30% reduction in waiting time.
The study compares grid‑connected and off‑grid energy options for AI data centers across the continental U.S., evaluating AC‑ and DC‑coupled solar‑plus‑storage, islanded natural gas, and grid interconnection. Using a technoeconomic framework that incorporates AI training loads, climate‑driven cooling, power conversion stages, and battery degradation, the authors introduce a speed‑adjusted cost of energy that accounts for compute unlocked by faster deployment. They find that DC coupling cuts lifetime energy costs by 18% versus AC, and when deployment speed is valued, DC‑coupled microgrids become the lowest‑cost option in 85% of locations, indicating that deployment speed outweighs unit energy cost for AI infrastructure.
arXiv:2608. 08761v1 Announce Type: cross Abstract: In an era defined by escalating climate change and the pervasive deployment of edge intelligence, the environmental cost of semiconductor manufacturing and operation has reached a critical threshold.
The MIT-developed tool "CrysVCD" uses AI to design new materials that are chemically stable in real-world conditions. By predicting stability early, it can significantly reduce the time and cost associated with testing and discarding unstable material designs.
arXiv:2607. 05408v1 Announce Type: cross Abstract: The environmental impact of training large language models (LLMs) is increasingly scrutinised, yet most published estimates focus on operational energy and disclose little about manufacturing (embodied) emissions, water consumption, or the underlying highperformance computing (HPC) infrastructure.
arXiv:2608. 14614v1 Announce Type: cross Abstract: As AI datacenters retire functional GPUs, vast quantities of still capable accelerators enter secondary markets.
arXiv:2607. 02531v1 Announce Type: cross Abstract: Water use by data centers is routinely reported as a single footprint, but water is consumed through two physically distinct pathways: at the site for cooling and in the power system that generates electricity.
What data teams need to build with AI to make self-healing data architecture a practical reality The post 7 Crucial Barriers Between Data Teams and Self-Healing Data Architecture appeared first on Towards Data Science .