The paper introduces a two-stage AI framework that synthesizes realistic, multi-view echocardiographic sequences from dynamic whole-heart meshes. Stage 1 uses an unpaired GAN‑diffusion model to convert extracted cross‑sections into ultrasound‑like frames, while Stage 2 applies masked video reconstruction to enhance temporal coherence and cardiac motion. Evaluation shows that the combined approach yields high realism at the frame level and significantly improves video‑level motion quality and consistency, offering a scalable source of annotated data for augmenting datasets and developing multi‑view cardiac assessment methods.
By Jo\~ao Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge, Sandro Queir\'os
arXiv:2403.19880v2 Announce Type: replace-cross
Abstract: Purpose: Large labeled echocardiography datasets are costly to collect. We use diffusion models to generate synthetic training data for segme...
By Milad Yazdani, Pooria Ashrafian, Moein Heidari, Alireza Rafiei Sardouei, Dena Shahriari, Ilker Hacihaliloglu
Echocardiography assesses the structure and function of the heart. Cardiologists read each study across several standard views and report the findings visible in those views by cardiac structure. AI f...
EchoAlign is a vision‑language foundation model for echocardiography that aligns each cardiac structure, video, and study with its corresponding report text, using a visibility matrix to restrict supervision to the views that actually depict each structure. Trained on 2.87 million videos and images from 159 clinical centers, it outperforms five public foundation models on 0.47 million test videos from ten unseen external datasets, achieving a mean AUROC of 0.890 for classification and a mean quadratic weighted kappa of 0.530 for severity grading. The model can detect findings, grade severity, estimate measurements, and segment cardiac structures across 62 clinical findings.
By Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol, Joshua Penn, Klaus H. Maier-Hein, Numan Saeed, Mohammad Yaqub
arXiv:2610.05603v2 Announce Type: replace
Abstract: Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, lo...
By Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen, Devika Subramanian
arXiv:2603.22179v2 Announce Type: replace
Abstract: Cardiovascular disease remains the leading cause of global mortality, with progress hindered by human interpretation of complex cardiac tests. Curr...
By Jack W O'Sullivan, Mohammad Asadi, Lennart Elbe, Akshay Chaudhari, Tahoura Nedaee, Francois Haddad, Ivan Lopez, Fang Cao, Michael Salerno, Li Fe-Fei, Ehsan Adeli, Rima Arnaout, Euan A Ashley
arXiv:2606. 14759v1 Announce Type: cross Abstract: Cine cardiac magnetic resonance is the gold standard for assessing cardiac function, but the scarcity of public datasets limits the development of advanced data-driven models.
By Yiheng Cao (SyCoIA - IMT Mines Al\`es), Gustavo Andrade-Miranda (SyCoIA - IMT Mines Al\`es), Jiatian Zhang, Guillaume Sall\'e, Xin Gao
arXiv:2603. 08505v2 Announce Type: replace-cross Abstract: Electrocardiography (ECG) is a low-cost, widely used modality for diagnosing electrical abnormalities like atrial fibrillation by capturing the heart's electrical activity.
By Michelle Espranita Liman, \"Ozg\"un Turgut, Alexander M\"uller, Eimo Martens, Daniel Rueckert, Philip M\"uller
arXiv:2609.08043v1 Announce Type: cross
Abstract: Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating te...
By Jiyoo Noh, Jonathan H. Chan
The paper introduces DPIF, a plug‑and‑play dual‑path interaction framework that can be integrated with any encoder‑decoder segmentation network. DPIF aligns cross‑view distributions using Sinkhorn optimal transport, decouples features via conditional mutual information to transfer knowledge within shared semantic spaces, and applies persistent homology‑based topological regularization to encode anatomical invariants. Experiments on a private echocardiography dataset and two public datasets show that DPIF‑enhanced models outperform single‑view baselines and achieve comparable performance to full‑data single‑view models while using only 40–60% of the data.
By Shuhuan Wang, Yuanyuan Cui, Pengju Wang, Huimin Guo, Ling Yue, Yin Gu, Yanchao Zhang, Wei Feng, Yunhe Liu, Wei Qian, Mingjun Xu, Shuang Liu, He Ma
The paper introduces SV-Cine, a cardiac MRI segmentation framework tailored for single ventricle physiology (SVP). It combines a generative data augmentation pipeline that creates synthetic 3D cardiac meshes and MRI, with a diagnosis-conditioned adaptation of the CineMA foundation model that uses patient-level diagnostic information to improve segmentation. Evaluations on an internal cohort show high Dice scores for left and right ventricles, outperforming nnU-Net, and demonstrate that incorporating diagnosis priors can adapt a pretrained model to specialized SVP tasks.
By Lila Cunge, Yuehong Liu, Hang Xu, Thomas Coudert, Pierangelo Renella, J Paul Finn, William Hsu, Kim-Lien Nguyen
EchoDiST is an unsupervised framework for estimating myocardial motion in echocardiography. It combines self‑distillation joint learning of anatomical segmentation and motion estimation with a diffusion‑conditioned network, requiring only limited anatomical annotations. The method achieves statistically significant improvements in anatomical alignment, strain assessment, and functional metrics across three datasets, outperforming seven other learning‑based approaches.