arXiv Computer Vision

FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement

arXiv AI
Oct 15

PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

arXiv:2509.19774v3 Announce Type: replace-cross Abstract: Electrocardiography (ECG) is the clinical gold standard for cardiovascular disease (CVD) assessment, yet continuous monitoring is constrained...

By Xiaocheng Fang, Jiarui Jin, Haoyu Wang, Che Liu, Jieyi Cai, Yujie Xiao, Guangkun Nie, Bo Liu, Shun Huang, Hongyan Li, Shenda Hong
arXiv Machine Learning
Aug 6

Prototype-based Self-Supervised Multimodal Learning for PPG and Accelerometry Signals

arXiv:2510. 09764v2 Announce Type: replace Abstract: Modeling multi-modal time-series data is critical for capturing system-level dynamics, particularly in biosignals where modalities such as ECG, PPG, EDA, and accelerometry provide complementary perspectives on interconnected physiological processes.

By Wanting Mao, Maxwell A Xu, Harish Haresamudram, Mithun Saha, Santosh Kumar, James Matthew Rehg
arXiv Computer Vision
Sep 25

$\unicode{x1F493}$Heartian: Physiology-Aware Relightable Gaussian Head Avatar

The paper introduces Heartian, a physiology‑aware framework that augments Gaussian head avatars with cardiac‑cycle‑dependent albedo modulation, enabling the encoding of remote photoplethysmography (rPPG) signals. By supervising with synchronized contact PPG, the method models the cardiac waveform as a sum of two Gaussians and learns per‑frame spatial residuals via a lightweight MLP. Experiments on 152 stationary recordings from UBFC‑rPPG, PURE, and MMPD show heart‑rate estimation errors as low as 0.29 bpm MAE and 0.38 % MAPE, while preserving reconstruction quality with negligible PSNR loss.

By Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Ak\c{s}it
arXiv AI
Oct 7

Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation

The paper introduces cylindrical geodesic flow matching, a method for translating quasiperiodic cardiovascular waveforms between different body locations. By replacing the standard affine path in flow matching with a closed‑form geodesic on a phase–amplitude cylinder, the approach preserves amplitude and instantaneous frequency during interpolation. Experiments on photoplethysmography and seismocardiography data show that this geometry‑aware method outperforms interpolation baselines and matches or exceeds supervised models, reducing error metrics by up to ~15%.

By Onur Selim Kilic, Afra Nawar, Cem Okan Yaldiz, Michael J. Cho, Ahmet Rasim Emirdagi, Demet Tangolar, Amirali Aghazadeh, Amit J. Shah, Omer T. Inan