The study uses 256‑channel EEG recordings from 62 male participants to classify hypnotic susceptibility during Guided Imagery with two‑dimensional convolutional neural networks, avoiding manual feature extraction. A sliding‑window approach tested 868 models across seven brain regions and 124 ten‑second windows, with the best single‑window model achieving 0.82 accuracy on a random split. In leave‑one‑subject‑out cross‑validation, anterior cortical regions—especially the frontal area—showed the most generalisable performance, with an ensemble of ten windows boosting frontal accuracy to 0.738, while occipital results collapsed to chance, indicating subject‑specific EEG fingerprints.
By Krzysztof Wrobel, Grzegorz M. Wojcik, Filip Postepski, Andrzej Kawiak, Katarzyna Zemla, Grzegorz Sedek
arXiv:2607. 27655v1 Announce Type: new Abstract: Reported accuracy in electroencephalography (EEG) emotion recognition depends on the complete evaluation procedure, not only the classifier.
By Hanting Suo, Yuwen Li
The paper investigates whether brief, minimally processed EEG segments can differentiate individuals labeled as extraverted or introverted by the Myers–Briggs Type Indicator. Using a subject‑independent nested 5‑fold cross‑validation, the authors compared EEGNet, EEGProgress, and a new compact convolutional network called SSCNet. SSCNet achieved the highest mean accuracy (0.6481), AUC (0.7063), and F1‑score (0.6276), exhibited the lowest variability across folds, and proved computationally efficient with the shortest training epoch time and highest throughput.
By Filip Postepski, Grzegorz M. Wojcik
This study examines whether short, minimally preprocessed EEG segments contain sufficient information to distinguish between individuals classified as extraverted or introverted according to the Myers...
The study evaluated whether imagined speech decoded from scalp EEG can transfer across individuals using three public datasets. Across 482 participant pairs, cross‑subject decoding accuracy was essentially at chance, while within‑subject decoding only surpassed chance in one dataset. The results suggest that imagined‑speech content does not generalize between people and that larger single‑condition datasets are more beneficial than further model development.
By Blessing Isoyiza Adeika, Onyema Osuagwu
The paper introduces TriX-EEG, a three-level framework for evaluating EEG artifact removal models. Level 1 assesses signal validity by measuring reconstruction quality and neural band‑power preservation. Level 2 evaluates removal faithfulness through artifact error and leakage, while Level 3 examines explanation reliability via temporal alignment, causal relevance, and stability. Experiments on nine denoisers across multiple benchmarks show that reconstruction metrics alone are insufficient, and that TriX‑EEG provides a more comprehensive assessment of model performance and explainability.
By Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran, Ian McLoughlin, Roozbeh Razavi-Far, Hung Cao
arXiv:2607.27655v2 Announce Type: replace
Abstract: Checkpoint selection can improve an electroencephalography (EEG) emotion-recognition score without improving performance on other trials. We compar...
By Hanting Suo, Hongxun Wang, Yuwen Li
Purpose. Electroencephalography (EEG) montages, channel counts and recording lengths vary widely, but most EEG foundation models are bound to the channel set and input length they were trained on. We...
The paper evaluates five publicly released EEG foundation models and an in‑house JEPA‑style model using a protocol that includes three key controls: an untrained encoder, spectral band‑power features, and a probe layer selected without test‑set look‑ahead. The study finds that selecting the probe layer by test score can modestly improve peak performance and alter the peak‑versus‑output relationship, that random initialization can match or surpass pretraining on certain tasks, and that full fine‑tuning rarely yields gains beyond seed variability. These findings lead the authors to propose four new reporting practices and to release all experimental results for re‑analysis.
By Mingyu Jeon, Suwan Cho, Jae Young Suh
arXiv:2607. 06630v1 Announce Type: new Abstract: Formal robustness certificates for embedded neural-interface models can pass while task accuracy collapses: at perturbation budget e=0.
By Jasmeet Singh Bindra
NOMAD-EEG is a 12‑million‑parameter diffusion model that learns EEG representations independent of electrode number, identity, or recording length by using 3D scalp positions and state‑space layers over time. Trained on 147 h of unlabelled EEG from a single corpus, it outperformed seven larger foundation models across ten datasets, achieving superior accuracy on tasks such as seizure detection, epilepsy diagnosis, motor imagery, and P300 detection. The model’s compact size and single‑corpus training yet strong performance demonstrate the feasibility of a versatile, lightweight EEG foundation model.
By Abdulkader Helwan, Khadidja Henni, Lina Abou-Abbas
arXiv:2605.18251v2 Announce Type: replace-cross
Abstract: Self-initiated attention shifts play a critical role in voluntary behavior but are difficult to study due to the absence of explicit temporal...
By Yuwen Zeng, Dengzhe Hou, Zhang Zhang, Sai Sun, Yongsong Huang, Chia-huei Tseng, Satoshi Shioiri