arXiv:2506. 02260v5 Announce Type: replace-cross Abstract: Wearable devices enable continuous multi-modal physiological and behavioral monitoring, yet analysis of these data streams faces fundamental challenges including the lack of gold-standard labels and incomplete sensor data.
By Howon Ryu, Yuliang Chen, Yacun Wang, Andrea Z. LaCroix, Chongzhi Di, Loki Natarajan, Yu Wang, Jingjing Zou
arXiv:2608. 07385v1 Announce Type: cross Abstract: Learning disentangled representations is a key requirement for developing versatile, general-purpose, and sustainable models in multi-modal wearable computing.
By Ioannis Ziogas, Ensieh Khazaei, Bilal Taha, Aamna Al Shehhi, Ahsan H. Khandoker, Leontios J. Hadjileontiadis, Dimitrios Hatzinakos
arXiv:2607. 27635v1 Announce Type: cross Abstract: Wearable sensors continuously capture fine-grained multivariate time-series data, providing opportunities to model behavioural patterns associated with health outcomes.
By Xiaotong Yu, Joshua Y. Kim, HaeJin Lee, Kalina Yacef
arXiv:2606. 27886v1 Announce Type: new Abstract: Recent advances in Human Activity Recognition (HAR) from wearable sensors have shown that multi-modal deep learning models consistently outperform their uni-modal counterparts.
By Ahmed Mohamady, Robin Burchard, Kristof Van Laerhoven
CIG-MAE is a self‑supervised framework for WiFi‑based human action recognition that uses a cross‑modal masked autoencoder to reconstruct both amplitude and phase of Channel State Information. It introduces an adaptive, information‑guided masking strategy that focuses on high‑density time‑frequency regions and employs a Barlow Twins regularizer to align cross‑modal representations without negative samples. Experiments on three public datasets show that CIG‑MAE outperforms state‑of‑the‑art SSL methods and even surpasses a fully supervised baseline, highlighting its data efficiency, robustness, and generalization.
By Gang Liu, Yanling Hao, Yixuan Zou
The paper introduces a new evaluation protocol for deep multivariate imputation models on wearable device data, addressing the issue of structured missingness where sensor features drop out together. Using a Garmin smartwatch dataset from an epilepsy patient, the authors generate realistic block-missing patterns from training data and show that matching the training protocol to this distribution reduces BRITS’ mean absolute error by 43%. They also extend BRITS with time‑of‑day encoding and compare it to linear interpolation and SAITS, finding that no single model dominates and that model rankings vary with evaluation design.
By Skye Goodman, Roussel Desmond Nzoyem, Leandro Junges, Peter Kissack, Yasser Qureshi, Amberly Brigden, Jeff Clark, Nawid Keshtmand