arXiv Computation and Language By Mohammed Nayeem Khan, Logesh L

Maya a1: Do the Options Read the Model, or Does Their Position? Order Sensitivity in a Non-Autoregressive Decision Model

Read the original on arXiv Computation and Language →

The paper investigates whether a non‑autoregressive decision model, Laya, is sensitive to the order of multiple‑choice options. By re‑engineering a 421M‑parameter checkpoint and rotating or permuting options on 951 Qwen‑verified questions, the authors find that the model’s answer changes for 25.8% of cases, with a 10.1‑point accuracy gap between first and last positions. Fine‑tuning with shuffled data reduces the flip rate to 7.2%, and a confidence‑weighted vote over multiple orderings yields a modest accuracy gain at higher compute.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv Computation and Language.

arXiv AI
Nov 14

Where in the Input Does a One-Pass Decision Encoder Look?

The paper evaluates Laya, a small model that processes a multiple‑choice question, its options, and a text in a single 512‑token sequence. Experiments show that when the relevant evidence lies beyond the window, accuracy drops to about 26–27%, and confidence metrics fail to warn of truncation. Fine‑tuning on longer documents improves performance on visible evidence but not on cut evidence, and a larger window or a 312‑token scan can yield modest gains.

By Mohammed Nayeem Khan, Allan Kevin T
arXiv AI
Oct 15

A, B, C, or Stable? Accuracy and Order Sensitivity Diverge in LLM Multiple-Choice Evaluation

The paper investigates whether accuracy and order sensitivity in large language model (LLM) multiple‑choice question (MCQ) evaluation move together. Using proprietary and open‑weight models on MMLU and ARC‑Challenge, the authors measure order sensitivity with flip rate and recall standard deviation (RStd) and find that these metrics often diverge from accuracy and from each other. They conclude that accuracy alone is insufficient and recommend reporting both flip rate and RStd alongside accuracy.

By Karl Hanna, Chen Feng
arXiv Machine Learning
Oct 16

One Bias Score, Two Factors: How Mitigations Affect Option Bias in Multiple-Choice Evaluation

The paper introduces the pooled selection-rate standard deviation (pooled SD) as a way to quantify how unevenly multiple-choice option letters are chosen across different orderings. It shows that pooled SD decomposes into two label‑free factors: the flip rate, which measures how often a model’s chosen option changes with ordering, and the positional skew, which captures the variability in option‑letter selection rates. Experiments on 41 checkpoints and 12 benchmarks reveal that prior correction mainly reduces positional skew, while aggregating each ordering with its reversal mainly reduces flip rate; applying both mitigations together further narrows the accuracy range across answer letters.

By Hyunjong Ok, Minjae Park, Jaeho Lee
arXiv Computation and Language
Oct 28

3, 7, 14, 17, 42: Instruction Tuning Installs and Sharpens Number-Choice Heuristics in Language Models

The study measures the exact probability that language models assign to each integer from 1 to N when prompted for a random number, eliminating sampling noise by summing over all spellings. Across 18 open‑weight models and 29 decoding settings, instruction tuning consistently makes the distribution less uniform, introducing a round‑number avoidance heuristic and sharpening endpoint avoidance. While tuned models rarely output the extreme values 1 or N and largely avoid multiples of 10, they do not converge on a single favorite integer across models.

By Samar Ansari
arXiv AI
4d ago

A System 1 Decision Model for Medical Multiple-Choice Questions Built on Frozen Language Models

The paper presents a System 1 decision model that answers medical multiple‑choice questions in a single pass using frozen language models. By converting the question and each option into vectors and applying two small trained projection heads, the model selects the closest option in a shared space. Experiments on MedMCQA with Qwen3.5‑0.8B, Granite‑4.2‑3B, and Qwen3‑8B achieve accuracies ranging from 33 % to 46 %, demonstrating that the approach is a cheap, fast baseline but not competitive with state‑of‑the‑art systems.

By Pavan Kumar Mantha